Keep children away from the air 

compressor at all times. 

 

Do not operate the product when 

fatigued or under the influence of 

alcohol or drugs. Stay alert at all 

times. 

 

Never defeat the safety features of 

this product. 

 

Equip area of operation with a fire 

extinguisher. 

 

Do not operate machine with 

missing, broken, or unauthorized 

parts. 

 

Never stand on the compressor

 

 

25.

 

  RISK OF FALLING

 

WHAT CAN HAPPEN: 

A portable 

compressor can fall from a table, 

workbench, or roof causing damage to 

the compressor and could result in 

serious injury or death to the 

operator.

 

HOW TO PREVENT IT:

 

Always operate 

compressor in a stable secure position 

to prevent accidental movement of 

the unit. Never operate compressor on 

a roof or other elevated position. Use 

additional air hose to reach high 

locations. 

26. 

RISK FROM NOISE

 

WHAT CAN HAPPEN: 

Under some 

conditions and duration of use, noise 

from this product may contribute to 

hearing loss. 

HOW TO PREVENT IT:

 

Always wear 

proper hearing protection during use. 

 

27. AIR RECEIVER

 

Over pressurizing the air receiver 

could cause personal injury or material 

damage. To protect from over 

pressurizing, a factory pre-set safety 

valve is installed.

 

 

WARNING: 

NEVER WELD, 

DRILL, OR CHANGE THE AIR 

 

RECEIVER IN ANY WAY.

 

Any replacement parts should be 

purchased with the same 

specifications as the original 

equipment. Please contact the 

authorized dealer for replacement 

parts or specifications.

 

 
 

28. SAFETY VALVE 

This valve is factory installed to 

prevent over pressurizing of the air 

receiver. 
It is factory set at a specific limit for 

your particular model, and should 

never be tampered with.

 

Adjustment by user will 
automatically void the warranty.

 

 

 

WARNING: 

DO NOT 

REMOVER, MAKE

 

ADJUSTMENTS TO OR SUBSTITUTE 

THIS VALVE!

 

 

 

EXTENSION CORDS

 

THE USE OF EXTENSION CORDS IS 

NOT RECOMMENDED. 

If the use of an 

extension

 

cord is unavoidable, be sure 

Содержание A12101

Страница 1: ...l before assembling operating and maintaining this unit You are responsible for operating the product properly safely Version V1 20171222 A A V I X O U T D O O R S FOR SERVICE CALL USA 1 866 591 8921...

Страница 2: ...l cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be...

Страница 3: ...pressor use and care a Do not use the compressor if the power Switch does not turn it on and off Any compressor that cannot be controlled with the power Switch is dangerous and must be repaired b Disc...

Страница 4: ...hever is greater 10 Industrial applications must follow OSHA guidelines 11 Maintain labels and nameplates on the compressor These carry important safety information If unreadable or missing contact ou...

Страница 5: ...w the compressor to operate unattended HOW TO PREVENT IT Always remain in attendance with the product when it is operating Always turn off and unplug unit when not in use Do not leave compressor unatt...

Страница 6: ...k of injury to consumers Your compressor air tank must be removed from service by the end of the year shown on your tank warning label The following conditions could lead to a weakening of the air tan...

Страница 7: ...TO PREVENT IT Never operate the compressor outdoors when it is raining or in wet conditions Never operate compressor with protective covers removed or damaged 2 WHAT CAN HAPPEN Repairs attempted by un...

Страница 8: ...parts such as the pulley flywheel and belt can cause serious injury if they come into contact with you or your clothing HOW TO PREVENT IT Never operate the compressor with guards or covers which are d...

Страница 9: ...der some conditions and duration of use noise from this product may contribute to hearing loss HOW TO PREVENT IT Always wear proper hearing protection during use 27 AIR RECEIVER Over pressurizing the...

Страница 10: ...esulting in power loss to the motor and overheating Instead of using an extension cord increase the working reach of the air hose by attaching another length of hose to its end Attach additional lengt...

Страница 11: ...YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments Save this manual for future reference 1 Power Switch 2 Reset Button 3...

Страница 12: ...for this fan to blow air through the vent holes in large amounts You know that the cooling system is working when air is being expelled Air Compressor Pump not shown Compresses air into the air tank...

Страница 13: ...cated at least 12 30 5 cm away from the wall or other obstructions that will interfere with the flow of air The air compressor pump and shroud are designed to allow for proper cooling The ventilation...

Страница 14: ...ces Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician 7 Improper connection of the equipment grounding conductor can result in a...

Страница 15: ...ilter or a dryer all not provided as shown on Figure A and Figure B Consult your air tool s manual for needed accessories A Portable Air Supply Setup A Air Hose Connects air to tool B Filter Prevents...

Страница 16: ...of use H Air Hose Connects air to tool I Filter Prevents dirt and condensation from damaging tool or workpiece J Regulator Adjusts air pressure to tool K Lubricator optional For air tool lubrication L...

Страница 17: ...ies The regulator outlet pressure must never exceed the maximum pressure rating NOTE Risk of property damage Compressed air from the unit may contain water condensation and oil mist Do not spray unfil...

Страница 18: ...pressure switch The Compressor will turn on automatically when the air pressure drops to 85 PSI and will turn off automatically when the air pressure reaches 100 PSI WARNING TO PREVENT SERIOUS INJURY...

Страница 19: ...otor Overload Protector Automatic Shut Off System not shown The motor has a thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor mu...

Страница 20: ...mpressor NOTE The environment in which the compressor is used and the frequency of use can affect how often you will need to check the Air Compressor components and perform maintenance procedures DAIL...

Страница 21: ...Operation Air tanks contain high pressure air Keep face and other body parts away from outlet of drain Use ANSI Z87 1 eye protection CAN CSA Z94 3 when draining as debris can be kicked up into face W...

Страница 22: ...arts Personal injuries can occur Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure and allow the air compressor to cool 1 Release a...

Страница 23: ...ee To Drain Tank under Maintenance WARNING Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 3 Protect the electrical cor...

Страница 24: ...urely Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection inside terminal box 3 Incorrect power...

Страница 25: ...t start up again on its own See Motor Overload Protector in OPERATION section contact a trained service technician 5 Loose fittings 5 Reduce air pressure then check all fittings with a soap solution f...

Страница 26: ...lace with wider hose and or hose connections 9 High altitude reducing air output 9 Higher altitudes require compressors with greater output 10 Pressure switch adjusted too low or 10 Make necessary adj...

Страница 27: ...ion cord or eliminate extension cord See Recommended Wire Gauge for Extension Cords 6 Dirty compressor head cylinder intercooler 6 Clean with compressed air 7 Operating pressure too high 7 Reduce oper...

Страница 28: ...Excessive tank pressure safety valve pops off 1 Safety valve needs service 1 Pull on test ring of safety valve If it still pops replace 2 Pressure switch does not shut off motor when compressor reache...