AMT/PTD/TR/0001/3/7/EN
Installation Manual for digital sets - IP sets - SIP sets
Page
5-4 05/2008
To install sets and cartridges in the i7XX range
5.1.2.4
Access to the i780 configuration
Once powered up, the set displays i780 on the 1st line along with the software version
The set's " -- Rxyxyx-- " on the 2
nd
line. The set then displays a question mark.
" ? " on the 1st line and i780 followed by the software version " -- Rxyxyx-- " of the cartridge on the
2
nd
line.
The installer then has 5 seconds to enter one of the following sequences:
*1
to enter network parameters in the configuration menu, the first menu option "Phone number"
is displayed.
The password is the set's release code (default value 0000).
or
*7
to enter Ethernet parameters in the configuration menu, the first menu option "Auto
negotiation" is displayed.
The following commands are available:
: Next option
: Previous option
: Exit and validate the configuration programming
: Clear (one character at a time)
: Exit without validating the configuration programming
: Manually enter the IP address dot
Содержание M720
Страница 1: ...Gamme NeXspan Installation Manual Digital sets IP Sets SIP Sets AMT PTD TR 0001 3 7 EN 05 2008...
Страница 36: ...AMT PTD TR 0001 3 7 EN Installation Manual for digital sets IP sets SIP sets Page 3 2 05 2008 References...
Страница 150: ...AMT PTD TR 0001 3 7 EN Installation Manual for digital sets IP sets SIP sets Page 7 8 05 2008 i220 SIP set...
Страница 332: ...AMT PTD TR 0001 3 7 EN Installation Manual for digital sets IP sets SIP sets Page 13 2 05 2008 M7xx i7xx download tool...
Страница 334: ...AMT PTD TR 0001 3 7 EN Installation Manual for digital sets IP sets SIP sets Page 14 2 05 2008 Spare parts...
Страница 336: ...AMT PTD TR 0001 3 7 EN Installation Manual for digital sets IP sets SIP sets Page 15 2 05 2008 Maintenance...
Страница 352: ...AMT PTD TR 0001 3 7 EN Installation Manual Digital sets IP Sets SIP Sets Page 16 16 05 2008 Appendix...