Features
517
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
Tab. 327 Recording of malicious calls
Tab. 328 Recording of malicious calls: Prerequisites
Suffix dialling function
Tab. 329 Recording of malicious calls: Suffix dialling function
System configuration
Tab. 330 Recording of malicious calls: System configuration
Reference to Other Features
Interface
Operating sequence / signalling on the ter-
minal
Scope
B
Activate during the call / after the call during
the busy tone signalling
1)
.
Network provider confirms activation (the type
of signalling is specific to the network provider)
1)
The duration of the busy tone signalling after the call depends on the network provider.
Internal user
Connection restrictions:
• Only for external incoming connections
• In hands-free mode, activation is practi-
cally possible only during the call as sys-
tem phones hang up automatically within
a few seconds of the end of the call.
A
External user
Prerequisites
Communication server
Technical
The communication server must be directly connected with the ISDN network (no sup-
port in the private network)
Terminals:
• System phones (configurable only with AMS on the Office 10)
• ISDN terminals
Administrative
Must be applied for as a supplementary service from the network provider
Legal
A court injunction must be required depending on the legislation in the region con-
cerned
Function
System phones
ISDN terminal
Activate MCID
MCID is available as */# function F16#1# in the function
selection list, and can be configured onto a function key
Menu or function key
Parameter
Parameter value
Remarks
No settings
Features:
•