Identification elements
103
System functions and features as of R3.0
syd-0367/1.3 – R3.0 – 03.2013
Call to the Public Network via a Gateway PINX with Overflow Routing
and
Automatic CLIP
=
no
User B (330) on PINX 2 calls user F on the public network via PINX 3 as all the availa-
ble communication channels between PINX 2 and PINX 1 are busy.
PINX 3 does not have a DDI number for user B.
Automatic CLIP
=
no
is set in the user configuration of user B. The CLIP settings of
the user configuration are used:
•
CLIP number
= 55 555 55 53
•
NPI
=
E.164
•
TON
=
national
Fig. 40
Example 5: User B calls user F (excerpt from
Tab. 29
Example 5: Creating and presenting user B’s CLIP number
Step
CLIP number
NPI
TON
Description
1
330
PNP
level 0
User B
→
PINX 2
• A suitable DDI number is not searched for.
2
55 555 55 53
E.164
National
PINX 2
→
PINX 3
3
55 555 55 53
E.164
National
PINX 3
• CLIP No. is buffered unchanged
• A suitable DDI number is not searched for.
4
55 555 55 53
E.164
National
PINX 3
→
Exchange
• CLIP No. is sent unchanged to the public network.
5a
055 555 55 53
Exchange
→
User F
• Presentation on the terminal if special arrangement
5b
066 666 66 60
Exchange
→
User F
• Presentation on the terminal if special arrangement
is not available (see
).