Page 92
July 2019 – TD 304 OPERATING MANUAL – Doppler Current Profiler Sensor
3.7.4
Licensed Options
Figure 3-47: Licensed Options
Acoustic Wave Product Number
is only for factory use. Default value is The Acoustic Wave product number 5759.
Acoustic Wave Option Key
is used to enable the wave software. If Acoustic wave is ordered a license key with 8
unique numbers are delivered. A License key is generated using product number and serial number and cannot be used
on other instruments.
3.7.5
Wave Measurement
Figure 3-48: Wave Measurement
Select Active Wave Cell
. Default setting is Cell 1 the one closest to the surface but you can also select Cell 2 or Cell 3.
Each cell is 2 meter cell size and no overlap,
Enable Fixed Wave Cell Depth
. If enabled the
Wave Cell Center Depth
setting will be used to set the distance from
surface to first cell, If not set the distance will be dynamic and based on depth and wave condition
Wave Cell Center Depth
is the distance from surface to first cell center in meter.