Instruction manual BFM
25
is
3.6.5
Circulation pipe
See (C) in the installation diagram
(3.5 "Installation diagram")
.
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump (6) of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve (5) behind the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves for service purposes (4).
4. Connect the circulation pipe to the T-piece at the drain valve (9) as shown in
the drain valve figure
(3.6.4 "Drain valve")
.
3.7
Water connections,
Unvented
Warning
The installation should be carried out by an authorised installation engineer,
in compliance with general and local regulations
(1.3 "Regulations")
.
3.7.1
Cold water side
See (A) in the installation diagram
(3.5 "Installation diagram")
.
1. Fit an approved stop valve (4) on the cold water side as required by
applicable regulations
(1.3 "Regulations")
.
2. The maximum working pressure of the appliance is 8 bar. Because the
pressure in the water pipe at times can exceed 8 bar, you must fit an
approved pressure-reducing valve (1).
3. Fit a non-return valve (5) and an expansion vessel (16).
4. Fit an expansion valve (15) and connect the overflow side to an open
wastewater pipe.
3.7.2
Recirculation pipe
You can install a top to bottom circulation pump to prevent water stacking in the
boiler.
1. Optional: depending on the draw-off pattern, fit a recirculation pipe (Ø 22
mm), a stop valve (11) and a top to bottom circulation pump (7).
2. Fit a non-return valve (5).
3. Fit a stop valve (11).
3.7.3
Hot water side
See (B) in the installation diagram
(3.5 "Installation diagram")
.
Note
Insulating long hot water pipes will prevent unnecessary energy loss.
1. Optional: fit a temperature gauge (12) so you can check the temperature of
the tap water.
2. Fit the T&P valve (3).
3. Fit a stop valve (11) in the hot water outlet pipe for servicing.
3.7.4
Drain valve
1. Fit the standard drain valve (9) supplied with the appliance.
2. If applicable, fit a circulation pipe
(3.6.5 "Circulation pipe")
.
If not, fit the blind threaded plug and gasket (C) supplied with the drain valve,
as shown in the figure.
Содержание BFM - 100
Страница 1: ......
Страница 2: ......
Страница 4: ...4 Instruction manual BFM gis ...
Страница 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Страница 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Страница 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Страница 48: ...Draining 48 Instruction manual BFM 6 gis ...
Страница 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Страница 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Страница 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Страница 62: ...is Instruction manual BFM 62 ...
Страница 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Страница 74: ...0306 723 4 0 UK Index Instruction manual BFM ...