Installation
18
Instruction manual BFM
3
is
3.3.2
Maximum floor load
Allow for the appliance's weight with respect to the maximum floor load; refer to
the table.
3.3.3
Water composition
The appliance is intended for heating drinking water. The drinking water must
comply with the regulations governing drinking water for human consumption.
The table gives an overview of the specifications.
Water specifications
Note
If the water specifications deviate from those stated in the table, then the
tank protection cannot be guaranteed
(13 "Warranty (certificate)")
.
3.3.4
Working clearances
For access to the appliance, it is recommended that the following clearances
are observed (see figure):
•
AA: around the appliance's control column and cleaning openings: 100cm.
•
BB: all sides of the appliance: 50cm.
•
Above the appliance (room to replace the anodes):
-
100cm if using fixed anodes, or
-
50cm if using flexible anodes.
If the available clearance is less than 100cm, flexible magnesium anodes
may be ordered.
Note
When installing the appliance, be aware that any leakage from the tank
and/or connections can cause damage to the immediate environment or floors
below the level of the boiler room. If this is the case, the appliance should be
installed above a wastewater drain or in a suitable metal leak tray.
The leak tray must have an appropriate wastewater drain and must be at least
5cm deep with a length and width at least 5cm greater than the diameter of the
appliance.
Weight of the appliance filled with water
BFM 30 BFM 50 BFM 80 BFM 100
BFM 120
539 kg
543 kg
548 kg
573 kg
573 kg
Water composition
Hardness
(alkaline earth ions)
> 1.00 mmol/l:
•
German hardness> 5.6° dH
•
French hardness > 10.0° fH
•
English hardness > 7.0° eH
Conductivity
> 125 µS/cm
Acidity (pH value)
7.0 < pH value < 9.5
Содержание BFM - 100
Страница 1: ......
Страница 2: ......
Страница 4: ...4 Instruction manual BFM gis ...
Страница 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Страница 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Страница 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Страница 48: ...Draining 48 Instruction manual BFM 6 gis ...
Страница 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Страница 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Страница 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Страница 62: ...is Instruction manual BFM 62 ...
Страница 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Страница 74: ...0306 723 4 0 UK Index Instruction manual BFM ...