Instruction manual BFM
21
is
Dimensions (all measurements in mm unless otherwise indicated)
3.4.2
General and electrical specifications
General and electrical specifications
Dimens
ion
Description
BFM30
BFM50
BFM80
BFM100
BFM120
A
Total height
2000
2000
2020
2020
2020
B
Height of top of appliance
1800
1800
1820
1820
1820
C
Position on pallet
580
580
580
580
580
D
Appliance diameter
710
710
710
710
710
E
Depth
1000
1000
1000
1000
1000
F
Width
755
755
755
755
755
G
Diameter of chimney flue
80
100
130
130
130
Hy
y-position air supply
-
-
-
235
235
K
Height of gas connection
600
600
600
600
760
L
Diameter of Air supply
125
150
200
130
130
M
Height of cold water supply
600
600
590
590
590
N
Height of hot water outlet
1640
1640
1655
1655
1655
P
Height of cleaning opening
770
770
760
760
760
R
Height of drain valve connection
550
550
540
540
540
S
Height of T&P valve connection
1600
1600
1600
1600
1600
1
Cold water supply connection (external)
R1
1
/
2
R1
1
/
2
R1
1
/
2
R1
1
/
2
R1
1
/
2
2
Hot water outlet connection (internal)
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
3
Gas control connection (internal)
Rp
3
/
4
Rp
3
/
4
Rp
3
/
4
Rp
3
/
4
Rp1
4
Drain valve connection (internal)
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
5
T&P valve connection (internal)
1 - 11.5
NPT
1 - 11.5
NPT
Rp1
1
/
2
Rp1
1
/
2
Rp1
1
/
2
6
Cleaning/inspection opening
Ø 100
Ø 100
Ø 100
Ø 100
Ø 100
DESCRIPTION
Unit
BFM
30
BFM
50
BFM
80
BFM
100
BFM
120
Volume
litres
309
298
253
253
253
Maximum operating pressure
bar
8
8
8
8
8
Empty weight
kg
230
245
295
320
320
Heating-up time
Δ
T = 45
o
C
minutes
37
22
12
9
8
Diameter of air restrictor
mm
36
42
54
48
64
Number of anodes
-
2
2
4
4
4
Number of bar burners/orifices
-
3
5
7
7
7
Number of flue tubes/flue baffles
-
5
7
16
16
16
Electrical power consumption
W
100
100
100
275
300
Supply voltage
(-15% +10% VAC)
volts
230
230
230
230
230
Mains frequency
Hz (± 1Hz)
50
50
50
50
50
IP class
-
20
20
20
20
20
Содержание BFM - 100
Страница 1: ......
Страница 2: ......
Страница 4: ...4 Instruction manual BFM gis ...
Страница 10: ...Introduction 10 Instruction manual BFM 1 gis ...
Страница 16: ...Working principle of the appliance 16 Instruction manual BFM 2 gis ...
Страница 42: ...Conversion to a different gas category 42 Instruction manual BFM 4 is ...
Страница 48: ...Draining 48 Instruction manual BFM 6 gis ...
Страница 52: ...Status of the appliance 52 Instruction manual BFM 8 gis ...
Страница 54: ...Starting and running 54 Instruction manual BFM 9 gis ...
Страница 56: ...Shutting down 56 Instruction manual BFM 10 gis ...
Страница 62: ...is Instruction manual BFM 62 ...
Страница 72: ...Electrical diagram 72 Instruction manual BFM 14 is ...
Страница 74: ...0306 723 4 0 UK Index Instruction manual BFM ...