North American - ENG
Date Released:
05-22-18
TAM Application Monitor - Yype 21800
Page 13
44-0009-2048-6 / ECO# 0078483
Box Present Sensing Assembly
The box present sensing assembly consists of two
identical brackets. One is used to mount the sensor
and guard. The other is for mounting the re
fl
ector.
Each bracket uses a 3M™ VHB™ acrylic foam tape to
adhere the sensor/re
fl
ector bracket assemblies to the
case sealer. These brackets have tabs for alignment
"squaring" to the case sealer’s base or column. They
are also slotted to allow for additional adjustment of
sensor and re
fl
ector along the bracket length.
Mounting Procedure
The guidelines for positioning the sensor/re
fl
ector
brackets are listed below.
Figure 2-13
5) Remove the e-ring, roller, shaft, sensor and
bracket to position on correct side as illustrated
in
Figure 2-13.
6) Thread the sensor into bracket until the end of
the sensor is approximately. 1mm (.039”) from
end of roller. Check to insure all seven targets
are sensed as the roller turns.
1) Verify that the control box is properly mounted to
the case sealer.
2) Determine the appropriate mounting location for
your application. The box present sensor can be
mounted at various locations from a point ahead
of the applying roller to the end of the cuto
ff
bracket. Whenever possible the sensor/re
fl
ector
brackets should be positioned approximately ½”
from the end of the lower taping head cuto
ff
bracket. For applications with top taping only
the position should be chosen using the upper
taping head cuto
ff
bracket. The sensor must also
be positioned to detect the lowest height box
without being blocked by taping head movement.
Mounting location and adjustment will vary with
each
application
(See Figures 2-14).
Important:
Do not remove the VHB
™
tape liner
to mount the box present sensor
brackets
fi
rst determine the sensor
beam
location.
3) Connect the box present sensor into the box
present control cable and turn power on.
4) Attach the sensor and re
fl
ector to the brackets.
Whenever possible place the re
fl
ector/bracket
assembly on the operator side of the machine
and sensor/bracket assembly on the opposite
side. This will reduce the chance of faults
caused by contacting and possibly altering the
sensor
alignment.
Note:
In certain applications the sensor and or
re
fl
ector can be attached directly to the
case
sealer.
The
re
fl
ector can be removed
from the bracket and attached using the
VHB™ tape supplied in this kit (i.e. 800
Series).
5) Move a box to the sensor location to turn on
(i.e. primary sensor location in front of cuto
ff
bracket or alternate as shown in
Figure 2-15
).
6) Position the Re
fl
ector and sensor brackets on
opposite sides of the machine close to the
fi
nal
position.
Figure 2-14
Alternate -
Side Belt Drive/
Low Box Height
Primary
Location
Cuto
ff
Bracket
Warning
•
To reduce the risk associated with
pinches, entanglement and
hazardous
voltage:
−
Turn electrical supply o
ff
and
disconnect before performing any
adjustments, maintenance or servicing
the machine or taping heads.
Installation and Set-Up
(continued)
Содержание Tape Application Monitor
Страница 6: ...5...
Страница 38: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 32 44 0009 2048 6 ECO 0078483...
Страница 46: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 40 44 0009 2048 6 ECO 0078483...
Страница 60: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 54 44 0009 2048 6 ECO 0078483...
Страница 61: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 55 44 0009 2048 6 ECO 0078483...
Страница 62: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 56 44 0009 2048 6 ECO 0078483...