North American - ENG
Date Released:
05-22-18
TAM Application Monitor - Yype 21800
Page 23
44-0009-2048-6 / ECO# 0078483
Loading Tape Supply Roll
The tape application monitoring system is indepen-
dent of the taping head. This allows you to remove
the taping head without having to disconnect any
electrical or pneumatic lines.
To remove or add a tape supply roll to the upper or
lower outboard tape drum:
1) Pull the spring loaded dancer arm away from the
tape roll until it contacts the holding magnet
(Figure 4-1).
The magnet will hold the dancer
arm away from the tape drum allowing you to
easily remove and install tape rolls.
2) Rotate the dancer arm away from the holding
magnet and allow it to rest on the new tape roll.
Figure 4-3
Wrong
Dancer Arm Position
Correct
Dancer Arm Posi-
tion
Note:
No magnets are used in standard lower taping
head applications (Tape bracket/drum attached to
the taping head). Simply lift from the case sealer to
replace the supply roll. Place the taping head back
into the machine with the new tape roll
(Figure 4-2).
4) Verify that the supply roll is contact the dancer arm
roller for proper operation.
3) Follow the standard threading procedure when
replacing the supply roll of the taping head.
Note:
It is possible to insert the supply roll behind
the dancer arm assembly roller
(Figure 4-3).
This will prevent proper operation and a no
apply tape fault will occur.
Note:
The Dancer arm roller is not part of the tape
path. Do not wrap tape around/over the
dancer arm roller.
•
To reduce the risk associated with mechanical and electrical hazards:
−
Read, understand, and follow all safety and operating instructions before operating or servicing
the case sealer.
−
Allow only properly trained and quali
fi
ed personnel to operate and service this equipment.
•
To reduce the risk associated with pinches, entanglement and hazardous voltage:
−
Turn electrical supply o
ff
and disconnect before performing any adjustments, maintenance or
servicing the machine or taping heads.
Warning
Figure 4-1
Figure 4-2
Operation
Содержание Tape Application Monitor
Страница 6: ...5...
Страница 38: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 32 44 0009 2048 6 ECO 0078483...
Страница 46: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 40 44 0009 2048 6 ECO 0078483...
Страница 60: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 54 44 0009 2048 6 ECO 0078483...
Страница 61: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 55 44 0009 2048 6 ECO 0078483...
Страница 62: ...North American ENG Date Released 05 22 18 TAM Application Monitor Yype 21800 Page 56 44 0009 2048 6 ECO 0078483...