78-8130-6151-8 Rev G
39
C. Alert Mode
While tracing a cable or pipe, it is possible to search for markers.
1. Press
Alert
[SK].
− If the unit is in Dir Pk, DirNull or Ind Pk,
a prompt will notify the operator that alert
mode only functions in Special Peak (Spl
Pk) mode.
2. Press
Mode
[SK Toggle] for Spl Pk.
3. Press
Alert On
[SK Toggle].
−
The receiver display will add the Alert bar
graph and the type of marker to the display
with a prompt to adjust the marker gain.
4. Press the
Gain
[4] until only a small mark on
the marker bar graph is visible.
5. Press
Locate/OK
[5] to save the marker gain
setting.
−
The screen will return to Special Peak Cable
Locate / Alert On.
−
If the selected type of utility marker is
detected, a second audio tone will emit from
the unit and the marker bar graph will fill.
The marker utility will default to the last
type of marker set in marker locate mode.
6. Press
Locate/OK
[5] +
Marker
[SK] +
Marker
1
[SK Toggle] to change the type of marker that
the unit will detect in alert mode.
7. Press
Locate/OK
[5] and then
Cable/Pipe
[SK]
to return to the locate mode with the newly
selected marker type now visible on the display.
Adjust the
Gain
[4] again (per Step 4 above)
and then press
Locate/OK
[5].