78-8130-6151-8 Rev G
29
2. Lower the tip of the receiver to the ground and
press
Depth
[SK].
−
The depth to the target cable or pipe is
displayed in the units specified in the
receiver set up menu. The bold current
reading is a relative current measurement.
This reading can be compared to the current
reading that alternately flashes with the
frequency on the transmitter to help identify
the target cable/pipe.The highest relative
current value will be the target cable/pipe
and will compare closest to the transmitter
relative current value. The milliamp reading
is an actual current measurement.
−
There are two options for measuring depth.
Live depth is a continuous measurement.
1-Shot Depth is an averaging of the depth
reading over a short period of time. When in
1-Shot mode, the unit will average the depth
reading for three seconds, and then display
the result on the screen. Press Depth [SK] to
alternate between the two modes.
−
Five depth readings can be saved with the
time, date and relative current measurements.
3. Pressing
Save
[SK] will place each entry in sequential order in memory (M1 - M5)
until five readings have been stored. The unit will overwrite saved entries in excess
of five, beginning with M1.
4. Press
Clear All
[SK] to delete all stored depth
information.
−
The operator may select the memory location
to store the depth readings by pressing Mem
Select [SK]. When the preferred location
appears on the screen, press Save [SK]. The
screen and memory location will populate
with the current information.
−
Each memory location can be reviewed by
pressing Mem Select [SK].
5. Press
Locate/OK
[5] to return to Locate Mode.