78-8130-6151-8 Rev G
55
Cross:
Red clip to the crossed conductor of one
pair; Black clip to the crossed conductor of the
other pair.
Figure 2
Ground:
Red clip to the faulted conductor;
Black clip to ground.
Figure 3
Split:
Red clip to Tip of Pair 1; Black clip to
Ring of Pair 1.
Figure 4
Verify Split:
Red clip to good conductor of
Pair 1; Black clip to split conductor of Pair 2
Figure 5
B. Cable Identification
Transmitter Setup
1. Connect the 3M™ Dyna-Coupler to the Transmitter
Output Jack
[T-6] using the
coupler cable.
Note: Cable Identification requires two Dyna-Couplers: one at the Transmitter and
one at the Receiver.
2. Clamp the Dyna-Coupler around the cable or both the tip and ring of a pair. Make
sure the jaws fully close.
3. Press and hold
off
[T-1] to perform a battery check.
4. Press
on: Ohm-meter/Fault Locate/Tone
[T-2] three times to set the transmitter to
Tone mode.