Parameter Description
Registrar IP Address
[RegistrarIP]
IP address and optionally port number of Registrar server.
Enter the IP address in dotted format notation, for example
201.10.8.1:<5080>.
If not specified, the REGISTER request is sent to the primary
Proxy server (see Proxy IP address parameter).
When port number is specified, DNS NAPTR/SRV queries are not
performed, even if DNSQueryType is set to 1.
Registration Time
[RegistrationTime]
Defines the time (in seconds) for which registration to a Proxy server is
valid. The value is used in the header Expires. In addition, this parameter
defines the time interval between Keep-Alive messages when
EnableProxyKeepAlive = 2 (REGISTER).
Typically a value of 3600 should be assigned, for one hour registration.
The gateway resumes registration according to the parameter
RegistrationTimeDivider.
The default value is 80. The valid range is 10 to 2000000.
Re-registration Timing (%)
[
RegistrationTimeDivider
]
Defines the re-registration timing (in percentage). The timing is a
percentage of the re-register timing set by the Registration server.
The valid range is 50 to 100. The default value is 50.
For example: If RegistrationTimeDivider = 70 (%) and Registration Expires
time = 3600, the gateway resends its registration request after 3600 x 70%
= 2520 sec.
Registration Retry Time
[RegistrationRetryTime]
Defines the time period (in seconds) after which a Registration request is
resent if registration fails with 4xx, or there is no response from the
Proxy/Registrar.
The default is 30 seconds. The range is 10 to 3600.
Subscription Mode
[SubscriptionMode]
Determines the method the gateway uses to subscribe to an MWI server.
Per Endpoint
[0]
= Each endpoint subscribes separately. This method is
usually used for FXS gateways (default).
Per Gateway
[1]
= Single subscription for the entire gateway. This method
is usually used for FXO gateways.
Enable Proxy Keep Alive
[EnableProxyKeepAlive]
Disable
[0]
= Disable (default).
Using OPTIONS
[1]
= Enable Keep alive with Proxy using OPTIONS.
Using REGISTER
[2]
= Enable Keep alive with Proxy using REGISTER.
If EnableProxyKeepAlive = 1, SIP OPTIONS message is sent every
ProxyKeepAliveTime. If EnableProxyKeepAlive = 2, SIP REGISTER
message is sent every RegistrationTime. Any response from the Proxy,
either success (200 OK) or failure (4xx response) is considered as if the
Proxy is correctly communicating.
This parameter must be set to 1 (OPTIONS) when Proxy
redundancy is used.
When EnableProxyKeepAlive = 2 (REGISTER), the homing
redundancy mode is disabled.
When the active proxy does not respond to INVITE messages
sent by the gateway, the proxy is marked as offline. The behavior
is similar to a Keep-Alive (OPTIONS or REGISTER) failure.
Содержание VCX V7111
Страница 30: ...30 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 44: ...44 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 53: ...3Com VCX V7111 VoIP Gateway User Guide 53 Readers Notes ...
Страница 54: ...54 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 211: ...3Com VCX V7111 VoIP Gateway User Guide 211 Figure 76 IP Connectivity Screen ...
Страница 235: ...3Com VCX V7111 VoIP Gateway User Guide 235 Readers Notes ...
Страница 236: ...236 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 240: ...240 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 245: ...3Com VCX V7111 VoIP Gateway User Guide 245 Readers Notes ...
Страница 246: ...246 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 281: ...3Com VCX V7111 VoIP Gateway User Guide 281 Readers Notes ...
Страница 282: ...282 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 298: ...298 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 315: ...3Com VCX V7111 VoIP Gateway User Guide 315 Readers Notes ...
Страница 316: ...316 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 319: ...3Com VCX V7111 VoIP Gateway User Guide 319 Readers Notes ...
Страница 320: ...320 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 346: ...346 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 351: ...3Com VCX V7111 VoIP Gateway User Guide 351 Readers Notes ...
Страница 352: ...352 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 376: ...376 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 386: ...386 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 394: ...394 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 396: ...396 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 405: ...3Com VCX V7111 VoIP Gateway User Guide 405 Reader s Notes ...
Страница 406: ...406 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 410: ...410 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 426: ...426 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 432: ...432 3Com VCX V7111 VoIP Gateway User Guide Figure 153 Prerecorded Tones Screen ...
Страница 452: ...452 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 456: ...456 3Com VCX V7111 VoIP Gateway User Guide Readers Notes ...
Страница 462: ...462 3Com VCX V7111 VoIP Gateway User Guide ...
Страница 464: ...464 3Com VCX V7111 VoIP Gateway User Guide ...