ini File Field Name
Web Parameter Name
Valid Range and Description
ExtBootPReqEnable
0 = Disable (default).
1 = Enable extended information to be sent in BootP request.
If enabled, the device uses the vendor specific information field in the BootP
request to provide device-related initial startup information such as board
type, current IP address, software version, etc. For a full list of the vendor
specific Information fields, see
1
Using BootP
.
The BootP/TFTP configuration utility displays this information in the ‘Client
Info’ column (see
Figure 131
).
This option is not available on DHCP servers.
Web and Telnet Parameters
Table 44
Web and Telnet Parameters
ini File Field Name
Web Parameter Name
Valid Range and Description
WebAccessList_x
[Web and Telnet Access List
Screen]
Defines up to ten IP addresses that are permitted to access the gateway’s
Web and Telnet interfaces. Access from an undefined IP address is denied.
This security feature is inactive (the gateway can be accessed from any IP
address) when the table is empty.
For example:
WebAccessList_0 = 10.13.2.66
WebAccessList_1 = 10.13.77.7
The default value is 0.0.0.0 (the gateway can be accessed from any IP
address).
WebRADIUSLogin
[Use RADIUS for
Web/Telnet Login]
Uses RADIUS queries for Web and Telnet interface authentication.
0 = Disabled (default).
1 = Enabled.
When enabled, logging to the gateway’s Web and Telnet embedded servers
is performed via a RADIUS server. The gateway contacts a predefined
server and verifies the given username and password pair against a remote
database, in a secure manner.
The parameter ‘EnableRADIUS’ must be set to 1.
RADIUS authentication requires HTTP basic authentication,
meaning the username and password are transmitted in clear text
over the network. Therefore, users are recommended to set the
parameter ‘HttpsOnly = 1’ to force the use of HTTPS, since the
transport is encrypted.
DisableWebTask
0 = Enable Web management (default).
1 = Disable Web management.
ResetWebPassword
Resets the username and password of the primary and secondary accounts
to their defaults.
0 = Password and username retain their values (default).
1 = Password and username are reset (for the default username and
password, see
Table 26
).
The username and password cannot be reset from the Web (i.e.,
via AdminPage or by loading an ini file).
Содержание V6100
Страница 28: ...28 V6100 and V7122 User Guide Reader s Notes...
Страница 48: ...48 V6100 and V7122 User Guide Reader s Notes...
Страница 72: ...72 V6100 and V7122 User Guide Reader s Notes...
Страница 80: ...80 V6100 and V7122 User Guide Reader s Notes...
Страница 151: ...V6100 and V7122 User Guide 151 Figure 83 Log off Prompt 2 Click OK in the prompt the Web session is logged off...
Страница 152: ...152 V6100 and V7122 User Guide Reader s Notes...
Страница 262: ...262 V6100 and V7122 User Guide Reader s Notes...
Страница 284: ...284 V6100 and V7122 User Guide Reader s Notes...
Страница 291: ...V6100 and V7122 User Guide 291 Figure 95 V7122 Startup Process...
Страница 324: ...324 V6100 and V7122 User Guide Reader s Notes...
Страница 354: ...354 V6100 and V7122 User Guide Reader s Notes...
Страница 374: ...374 V6100 and V7122 User Guide Reader s Notes...
Страница 382: ...382 V6100 and V7122 User Guide Figure 130 Example of a User Information File Reader s Notes...
Страница 392: ...392 V6100 and V7122 User Guide Reader s Notes...
Страница 409: ...V6100 and V7122 User Guide 409 Reader s Notes...
Страница 413: ...V6100 and V7122 User Guide 413 Reader s Notes...
Страница 425: ...V6100 and V7122 User Guide 425 Figure 145 UDP2File Utility Reader s Notes...
Страница 431: ...V6100 and V7122 User Guide 431 Reader s Notes...
Страница 447: ...V6100 and V7122 User Guide 447 Reader s Notes...
Страница 449: ...V6100 and V7122 User Guide 449 Figure 146 Connection Module CM Figure 147 OSN Server Figure 148 Hard Drive Module HDMX...
Страница 483: ...V6100 and V7122 User Guide 483 Reader s Notes...