By default, the value of number is 10.
Example
Set a maximum delay of 100 milliseconds for per fragmentation.
[3Com-Virtual-Template0] ppp mp lfi delay-per-frag 100
ppp mp max-bind
Syntax
ppp mp max-bind max-bind-num
undo ppp mp max-bind
View
Virtual template interface view
Parameter
max-bind-num: Indicates maximum number of links which can be bound, in the
range from 1 to 128.
Description
Using the ppp mp max-bind command, you can configure maximum number of
bound links of MP. Using the undo ppp mp max-bind command, you can restore
the default configuration.
By default, its value is 16.
Normally, it is not necessary to configure the parameter, which should be
performed under the guidance of technical engineers when necessary. Such a
configuration may have impact on the performance of PPP. If it is necessary to bind
more than 16 PPP channels, the parameter max-bind-num can be changed.
If a VIU board reports failure in MP removing links, it is possible that the maximum binding
number is smaller than the actually configured one. Make sure that the maximum binding number
should be larger than the actual one.
For the related command, see ppp mp.
Example
Set the maximum number of bound links to 12.
[3Com-Virtual-Template10] ppp mp max-bind 12
ppp mp min-fragment
Syntax
ppp mp min-fragment size
undo ppp mp min-fragment