ZXR10 5250 Series Command Reference
Parameter
Description
interval
<
1-65535
>
Interval (seconds).
<
mib-oid
>
Information path.
absolute
The sampling type of the alarm group is absolute sampling.
delta
The sampling type of the alarm group is delta sampling.
startup rising
The alarm group is triggered when the amount of data increases.
startup falling
The alarm group is triggered when the amount of data decreases.
both
The alarm group is triggered when the amount of data increases
or decreases.
threshold
<
1-65535
>
Threshold.
eventindex
<
1-65535
>
Event index.
rising
Rising event.
falling
Falling event.
<
name
>
Name of the owner.
vaild
The status of the alarm group is valid.
underCreation
The status of the alarm group is underCreation.
createRequest
The status of the alarm group is createRequest.
invalid
The status of the alarm group is invalid.
Examples
The following example sets the time interval of the alarm group whose index is 10 to 100
seconds:
set alarm 10 interval 100
The following example sets the sampling object of the alarm group whose index is 10 to
1.3.6.2.19.2:
zte(cfg-snmp)#set alarm 10 variable 1.3.6.2.19.2
The following example sets the sampling type of the alarm group whose index is 10 to
delta:
zte(cfg-snmp)#set alarm 10 sampletype delta
The following example sets that the alarm group whose index is 10 is triggered when the
amount of data increases:
zte(cfg-snmp)#set alarm 10 startup rising
The following example sets that the alarm group whose index is 10 triggers the alarm
whose index is 100 when the amount of data increases to 30000:
zte(cfg-snmp)#set alarm 10 threshold 30000 eventindex 100 rising
The following example sets the owner of the alarm group whose index is 10 to user1:
5-32
SJ-20131111172707-003|2013-11-27 (R1.0)
ZTE Proprietary and Confidential