ZXC10-BTS (V5.4) Installation Manual
10-26
1) Cut waterproof adhesive tapes about 200mm long;
2) Wrap the waterproof adhesive tapes from a low position where the connector is
connected and apply them about 200mm long to fill the low-lying parts of the
connector, as shown in Fig. 10.6-1.
Fig. 10.6-1 Wrap the Waterproof Adhesive Tapes (1)
3) Extend the adhesive tapes to double their length when wrapping them. The
direction of wrapping should be the same as the direction of screwing the feeder
connector, lest the feeder connector be loosened during the wrapping process.
4) As shown in Fig. 10.6-2, wrap the adhesive tapes layer by layer and then wrap
them again in the reverse direction. The upper layer covers the lower layer by
about 1/3 to avoid water penetration. Finally, reverse the direction and wrap
them layer by layer again. Apply the tape with three layers without any cut in the
entire process. Wrap the tapes around the feeder connector till they protrude
about 20mm from the feeder connector.
Fig. 10.6-2 Wrap the Waterproof Adhesive Tapes (2)
5) Grip the waterproof adhesive tapes after wrapping them to ensure firm bonding
between the tapes and the feeders/feeder connectors, as shown in Fig. 10.6-3.