Introducing Main Feeders into the Equipment Room
1. Precautions
●
Fig. 10.4-14 and Fig. 10.4-15 illustrate how the common feeders enter the
equipment room. Please ensure that the feeders will not bring any rain into the
equipment room when entering the equipment room. For that purpose, you can
design water curves as necessary.
Feeder window
Bent once with the
minimum diameter
more than 90mm
Indoor
Outdoor
Cabling rack
Feeder clip
Fig. 10.4-14 Method 1 of Introducing Feeders into the Equipment Room
Indoor
Feeder window
Cabling rack
Feeder clip
Bent once with the minimum
diameter more than 90mm
Fig. 10.4-15 Method 2 of Introducing Feeders into the Equipment Room
●
Use cabling racks both indoors and outdoors to guide the feeders when
introducing them through the feeder window into the equipment room.
2. Installation
procedure