R800
HANDBOOK
32
DTU Advanced Configuration
Step 3: If you want to work in the server working mode of the DTU, configure the parameters for the DTU in the working server
mode, as shown in Table 5-3-3.
Table 5-3-3 DTU Parameters
Parameter Name
Meaning
How to Configure
Enable
To enable/disable DTU.
Press the button to select.
Enable
Disable
Primary Center IP
DTU center server address.
Manual input.
Primary Center Port
DTU center server port.
Manual input.
Baud Rate
Serial port baud rate
Select Baud Rate to choose in the drop-down list from 115200, 57600,
38400, 19200, 9600, 4800, 2400, 1200, 600, 300
Data Bits
Serial port data transfer bits
Choose from data bits: 8, 7, 6, 5
Check Bits
Serial port check bits
Choose from check bits: None, Odd, Even
Device ID
Registered ID connected to data
8-digit hexadecimal number
SIM Card Number
Registered SIM card number connected to