7- 6
A B
c
Figure 7-7 HD/HDP contact installation
a)
Pinch the contact piece about 25 mm/0.984in after the crimping cylinder.
b)
Hold the connector so that the rear guard ring faces toward you.
c)
Push the contacts straight into the retaining ring until you hear a slight click. Gently pull to
confirm that the connector is fully locked.
Figure 7-8 HD/HDP lock contact position
Note: for unused wire cavities, a sealing plug should be inserted to achieve complete isolation from the
environment.
7.3.4 HD30/HDP20 Series Connector Removal
A B
Figure 7-9 HD/HDP contact removal