Configuring the Waveform Display
9650-0806-01 Rev. D
Propaq MD Operator’s Guide
3-7
Configuring the Waveform Display
You can display up to four waveform traces on the Waveform Display window. The first
waveform trace always uses an ECG lead as its source (such as
Pads
or Leads
l
,
ll
, or
lll
, and so
on. The default is
Pads
). If
Pads
are not connected, the unit can be configured to
automatically default to another ECG lead for the first trace. As you insert the remaining three
traces, you can specify that the traces use an ECG lead as the waveform source, or that the trace
derive its waveform from other available monitoring functions (such as
Resp
,
CO2
,
SpO2
or
IBP channels
P1
,
P2
, or
P3
).
If configured, the unit can display four ECG traces on startup, when no other monitoring
devices are attached.
The Propaq MD unit can also cascade a trace onto the adjoining trace area to double the
duration of the trace display.
On the Waveform Display window, to insert a new trace (
Insert
) or cascade (
Cascade
) a
displayed trace, highlight and select the trace label above the trace. In the following example,
the unit is configured to cascade the ECG Lead l trace:
Note:
The Propaq MD unit automatically inserts a new waveform when you turn on a
parameter (CO
2
) or a new sensor signal is present (SPO
2
, IBP). The Propaq MD unit
automatically removes a waveform when you turn off a parameter or remove a sensor
and the unit displays the resulting equipment alert.
06/06/2012 12:34:56
Adult
00:17:43
I, II,
III...
12
CO
2
Analyze
IBP
1 cm/mV
II
HR
bpm
80
121
79
(96)
NIBP
mmHg
38
12
BR
CO2
mmHg
SpO2
%
97
T1
ºF
98.6
Pads
III
aVL
aVF
V
Insert
Source
II
aVR
I
Cascade
Summary of Contents for Propaq MD
Page 1: ...Propaq MD Operator s Guide 9650 0806 01 Rev D...
Page 40: ...CHAPTER 1 GENERAL INFORMATION 1 28 www zoll com 9650 0806 01 Rev D...
Page 60: ...CHAPTER 2 PRODUCT OVERVIEW 2 20 www zoll com 9650 0806 01 Rev D...
Page 74: ...CHAPTER 4 TRENDS 4 4 www zoll com 9650 0806 01 Rev D...
Page 84: ...CHAPTER 5 ALARMS 5 10 www zoll com 9650 0806 01 Rev D...
Page 94: ...CHAPTER 6 MONITORING ECG 6 10 www zoll com 9650 0806 01 Rev D...
Page 104: ...Chapter 7 Monitoring Respiration Resp and Heart Rate HR 7 10 www zoll com 9650 0806 01 Rev D...
Page 120: ...CHAPTER 8 MONITORING NON INVASIVE BLOOD PRESSURE NIBP 8 16 www zoll com 9650 0806 01 Rev D...
Page 154: ...CHAPTER 11 MONITORING INVASIVE PRESSURES IBP 11 10 www zoll com 9650 0806 01 Rev D...
Page 160: ...CHAPTER 12 MONITORING TEMPERATURE 12 6 www zoll com 9650 0806 01 Rev D...
Page 186: ...CHAPTER 14 12 LEAD ECG INTERPRETIVE ANALYSIS 14 16 www zoll com 9650 0806 01 Rev D...
Page 212: ...CHAPTER 17 ADVISORY CPR PROTOCOL DEFIBRILLATION 17 6 www zoll com 9650 0806 01 Rev D...
Page 222: ...CHAPTER 18 EXTERNAL PACING 18 10 www zoll com 9650 0806 01 Rev D...
Page 240: ...CHAPTER 21 PATIENT DATA 21 6 www zoll com 9650 0806 01 Rev D...
Page 268: ...CHAPTER 22 COMMUNICATIONS 22 28 www zoll com 9650 0806 01 Rev D...
Page 284: ...CHAPTER 24 MAINTENANCE 24 12 www zoll com 9650 0806 01 Rev D...
Page 326: ...ACCESSORIES B 6 www zoll com 9650 0806 01 Rev D...