Defibrillator Controls and Indicators
9650-0806-01 Rev. D
Propaq MD Operator’s Guide
2–3
Table 2-2.
Propaq MD Controls and Indicators
Control or Indicator
Description
Display screen
Shows therapeutic settings, physiological waveforms and other
information for each monitored parameter, messages, time, and quick
access key labels.
Quick access keys
Seven buttons control different functions of the unit. Labels for the quick
access keys appear on the monitor display to the right of each key.
Auxiliary power LED
Illuminated when the unit is plugged in to an auxiliary power adapter.
Battery charge LED
Indicates battery status:
Steady yellow:
Battery is charging.
Steady green:
Battery is charged.
Alternating green and yellow:
The charge state cannot be determined
or a battery charging fault has been
detected.
No light:
Battery is not installed.
Visual alarm
indicators
Red, yellow, and green lights located on the top of the unit that flash on
and off when the unit is powered up and are used to indicate a patient
alert, equipment alert, and data transfer.
Pacer button
Displays pacer settings window to start/stop pacing activity or change
the rate, output, or mode settings.
Sync button
Activates the synchronized cardioversion mode.
Select Energy
buttons
Two sets of up-down arrow buttons control the selection of defibrillator
energy; one set is located on the front panel and the other set is located
on the STERNUM paddle.
Charge Button
Charges the defibrillator to the selected energy. In addition to the
Charge button on the front panel, there is one located on the APEX
paddle handle.
Shock Button
The front panel Shock button is only active when using hands-free
therapy electrodes or internal defibrillation paddles without a discharge
button. The Shock button illuminates when the device is charged and
ready.
To discharge the defibrillator when using paddles (internal or external)
with discharge buttons, press and hold the SHOCK buttons on the
paddles.
NIBP button
Starts/stops an NIBP measurement.
Snapshot button
Records 24 seconds of numeric and waveform data.
Summary of Contents for Propaq MD
Page 1: ...Propaq MD Operator s Guide 9650 0806 01 Rev D...
Page 40: ...CHAPTER 1 GENERAL INFORMATION 1 28 www zoll com 9650 0806 01 Rev D...
Page 60: ...CHAPTER 2 PRODUCT OVERVIEW 2 20 www zoll com 9650 0806 01 Rev D...
Page 74: ...CHAPTER 4 TRENDS 4 4 www zoll com 9650 0806 01 Rev D...
Page 84: ...CHAPTER 5 ALARMS 5 10 www zoll com 9650 0806 01 Rev D...
Page 94: ...CHAPTER 6 MONITORING ECG 6 10 www zoll com 9650 0806 01 Rev D...
Page 104: ...Chapter 7 Monitoring Respiration Resp and Heart Rate HR 7 10 www zoll com 9650 0806 01 Rev D...
Page 120: ...CHAPTER 8 MONITORING NON INVASIVE BLOOD PRESSURE NIBP 8 16 www zoll com 9650 0806 01 Rev D...
Page 154: ...CHAPTER 11 MONITORING INVASIVE PRESSURES IBP 11 10 www zoll com 9650 0806 01 Rev D...
Page 160: ...CHAPTER 12 MONITORING TEMPERATURE 12 6 www zoll com 9650 0806 01 Rev D...
Page 186: ...CHAPTER 14 12 LEAD ECG INTERPRETIVE ANALYSIS 14 16 www zoll com 9650 0806 01 Rev D...
Page 212: ...CHAPTER 17 ADVISORY CPR PROTOCOL DEFIBRILLATION 17 6 www zoll com 9650 0806 01 Rev D...
Page 222: ...CHAPTER 18 EXTERNAL PACING 18 10 www zoll com 9650 0806 01 Rev D...
Page 240: ...CHAPTER 21 PATIENT DATA 21 6 www zoll com 9650 0806 01 Rev D...
Page 268: ...CHAPTER 22 COMMUNICATIONS 22 28 www zoll com 9650 0806 01 Rev D...
Page 284: ...CHAPTER 24 MAINTENANCE 24 12 www zoll com 9650 0806 01 Rev D...
Page 326: ...ACCESSORIES B 6 www zoll com 9650 0806 01 Rev D...