5.1 Routine Maintenance
WARNING
To avoid risk of property damage, severe personal
injury or death, verify that all power is turned off
before starting this procedure.
Inspect the pump debris tray basket for debris by
looking through the clear pump lid. Remove any debris,
because as debris accumulates, it will begin to block the
flow of water through the pump. Keep the basket clean
to improve the performance of the pump.
1.
Turn off the power to the pump. If the pump
is located below the water level, close the
isolation valves on the suction and discharge
sides of the pump to prevent backflow of water.
2.
Turn the lid’s locking ring counter-clockwise
until ‘START’ aligns with the ports. Carefully
remove the lid. (A tool may used for leverage.)
CAUTION
A misaligned basket will cause the lid to be
improperly seated, allowing an air leak, which could
result in pump damage.
3.
Lift the basket out of the pump.
4.
Dispose of the debris and thoroughly clean
the basket, making sure all the holes are open.
Using a garden hose, spray the basket from the
outside to help clear the holes. Remove any
remaining debris by hand.
5.
Replace the basket in the pump by aligning
the opening with the suction pipe. If aligned
properly, the basket will drop easily into place.
Do not force it into place.
6.
Remove the lid seal and remove debris around
the lid seal seat, as this can allow air to leak into
the system. Clean the lid seal and place it on the
lid.
7.
Replace the lid with locking ring.
Hand-tighten
the lid to make an air-tight seal. Do not use any
tools to tighten the lid:
hand-tighten only.
8.
Verify that all valves have been returned to the
proper position for normal operation.
9.
Open the pressure release valve on the filter,
and make sure it is clean and ready for
operation.
10. Turn on the power to the pump. Once all the
air has been evacuated from the filter, close the
pressure release valve.
Zodiac Group Australia Pty Ltd strongly recommends
that you call a qualified service technician to perform
any repairs on the filter/pump system. To locate a
qualified technician, visit
www.zodiac.com.au
and click
on “
Pool Maintenance - Zodiac Product Support
”.
Adjustable Speed Mode
- to decrease speed by 50 rpm increments with
1000 rpm as the minimum limit.
- to save current speed setting and return to normal
operation mode.
Note:
Must hold for 10 seconds to
save required speed setting).
- HIGH speed is top speed of 2850 rpm, and can only
be adjusted by 50 rpm if already adjusted.
- will cancel change and revert back to original speed,
returning to normal operation mode.
- Press and hold , , for approximately 3-5 seconds
(until LED begins to flash) to switch to Adjustable Speed
Mode.
- Holding all 3 buttons down at the same time will reset to
default speeds.
Press Button:
Figure 4. Adjustable Speed Mode Operations