background image

Page 3 

ENGLISH

  

 

Zodiac VS FloPro

 Variable-Speed Pump   

|

   Installation & Operation Manual

Section 1. Important Safety Instructions 

READ AND FOLLOW ALL INSTRUCTIONS

1.1  Safety Instructions

All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. 

When installing and using this electrical equipment, basic safety precautions should always be followed, including the 

following:

 

WARNING

RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY 

OR DEATH.

 Do not block pump suction, as this can cause severe injury or death. Do not use this pump for 

wading pools, shallow pools, or spas containing bottom drains, unless the pump is connected to at least two 

(2) functioning suction outlets. Drain covers must be certified to the latest published edition of ANSI/ASME 

A112.19.8. 

 

WARNING

To reduce the risk of injury, do not permit children to use this product.

 

WARNING

To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full 

flow) valve position with the pump running.

 

WARNING

Incorrectly installed equipment may fail, causing severe injury or property damage.

 

WARNING

The pump is for fixed installations only and to be used in conjunction with swimming pool equipment (e.g. filters). 
The pump is to be installed in accordance with the relevant requirements of the Australian wiring rules NS/NZS 

3000.
Also refer to the installation instructions relating to the swimming pool equipment for which the pump will be an 

integral part. 
The pump is to be supplied through a residual current device (RCD) with a rated residual operating current of 

30mA.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qualified 

person in order to maintain proper safety conditions.

Summary of Contents for VS FloPro E3 Series

Page 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Page 2: ...uidelines 5 Section 2 General Description 5 2 1 Introduction 5 2 2 Description 5 Section 3 Installation Information 5 3 1 Plumbing 5 3 2 Electrical Installation 6 3 3 Conduct Pressure Testing 6 Sectio...

Page 3: ...dition of ANSI ASME A112 19 8 WARNING To reduce the risk of injury do not permit children to use this product WARNING To reduce the risk of property damage or injury do not attempt to change the backw...

Page 4: ...ssure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C Limit test to 24 hours After test visually check system to be sure it is ready for operation NOTICE These pa...

Page 5: ...bing 3 1 1 Preparation Information 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as cracks dents or a bent base If damage is found...

Page 6: ...quipment can be turned off This location must not be in the same area as the pool pump filter and other equipment 3 3 Conduct Pressure Testing WARNING When pressure testing a system with water air is...

Page 7: ...ten only Make sure all valves are open and the unions are tight 5 Restore power to the pump Then turn on the pump by following the instructions in the appropriate manual ePump Controller Owner s manua...

Page 8: ...easily into place Do not force it into place 6 Remove the lid seal and remove debris around the lid seal seat as this can allow air to leak into the system Clean the lid seal and place it on the lid 7...

Page 9: ...ump Loosen both unions and slide the pump out of the way Remove clean and re install both union o rings Reposition the pump next to the piping and secure the union nuts to the pump With clean union o...

Page 10: ...onal injury or death may occur if the pump starts while your hand is inside the pump 1 Turn off the pump Switch off the circuit breaker to the pump motor 2 Remove the lid and basket 3 Look inside the...

Page 11: ...he impeller counter clockwise to unscrew it 9 Inspect the impeller and diffuser for signs of rubbing and or damage 6 3 2 1 Impeller Reassembly 1 Press the new carbon face seal half see Figures 16 and...

Page 12: ...o ring 8 Slide the diffuser into the mating hole in the pump body While supporting the motor start two 2 screws on opposite sides This will hold the motor in position while you start the other six 6 s...

Page 13: ...erly disconnect the electrical wiring at the pump motor WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the VS FHP pump electrical circuit before starting the procedure W...

Page 14: ...has left the filter close the pressure relief valve NOTE Zodiac Pool Systems Inc recommends that the mechanical seals be replaced at the same time the motor is replaced See Section 6 3 3 Mechanical Se...

Page 15: ...Page 15 ENGLISH Zodiac VS FloPro Variable Speed Pump Installation Operation Manual 7 2 Exploded View...

Page 16: ...nal S A S U used under license All trademarks referenced herein are the property of their respective owners 2012 Zodiac Pool Systems Inc H0394700 Rev A 1212 Zodiac Group Australia 219 Woodpark Road Sm...

Reviews: