WARNING

To minimize the risk of severe injury or death, the filter and/or pump should not be subjected to the piping system 

pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are 

generally not intended to apply to the pool equipment such as filters or pumps.
Zodiac

®

 pool equipment is pressure tested at the factory.

However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter 

and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and 

secured before testing.

•  RELEASE ALL AIR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.

•  Water temperature for test must NOT EXCEED 100°F (38°C).

•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

NOTICE

: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult  equipment 

manufacturer.

CAUTION

Do not start pump dry! 

Running the pump dry for any length of time will cause severe damage and will void the 

warranty.

 

WARNING

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to 

fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment. 

CAUTION

This pump is for use with permanently installed pools and may also be used with hot tubs and spas, if so marked. 

Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building 

such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily 

disassembled for storage and reassembled to its original integrity.

Summary of Contents for VS FloPro E3 Series

Page 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Page 2: ...uidelines 5 Section 2 General Description 5 2 1 Introduction 5 2 2 Description 5 Section 3 Installation Information 5 3 1 Plumbing 5 3 2 Electrical Installation 6 3 3 Conduct Pressure Testing 6 Sectio...

Page 3: ...dition of ANSI ASME A112 19 8 WARNING To reduce the risk of injury do not permit children to use this product WARNING To reduce the risk of property damage or injury do not attempt to change the backw...

Page 4: ...ssure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C Limit test to 24 hours After test visually check system to be sure it is ready for operation NOTICE These pa...

Page 5: ...bing 3 1 1 Preparation Information 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as cracks dents or a bent base If damage is found...

Page 6: ...quipment can be turned off This location must not be in the same area as the pool pump filter and other equipment 3 3 Conduct Pressure Testing WARNING When pressure testing a system with water air is...

Page 7: ...ten only Make sure all valves are open and the unions are tight 5 Restore power to the pump Then turn on the pump by following the instructions in the appropriate manual ePump Controller Owner s manua...

Page 8: ...easily into place Do not force it into place 6 Remove the lid seal and remove debris around the lid seal seat as this can allow air to leak into the system Clean the lid seal and place it on the lid 7...

Page 9: ...ump Loosen both unions and slide the pump out of the way Remove clean and re install both union o rings Reposition the pump next to the piping and secure the union nuts to the pump With clean union o...

Page 10: ...onal injury or death may occur if the pump starts while your hand is inside the pump 1 Turn off the pump Switch off the circuit breaker to the pump motor 2 Remove the lid and basket 3 Look inside the...

Page 11: ...he impeller counter clockwise to unscrew it 9 Inspect the impeller and diffuser for signs of rubbing and or damage 6 3 2 1 Impeller Reassembly 1 Press the new carbon face seal half see Figures 16 and...

Page 12: ...o ring 8 Slide the diffuser into the mating hole in the pump body While supporting the motor start two 2 screws on opposite sides This will hold the motor in position while you start the other six 6 s...

Page 13: ...erly disconnect the electrical wiring at the pump motor WARNING ELECTRICAL SHOCK HAZARD Turn off all switches and the main breaker in the VS FHP pump electrical circuit before starting the procedure W...

Page 14: ...has left the filter close the pressure relief valve NOTE Zodiac Pool Systems Inc recommends that the mechanical seals be replaced at the same time the motor is replaced See Section 6 3 3 Mechanical Se...

Page 15: ...Page 15 ENGLISH Zodiac VS FloPro Variable Speed Pump Installation Operation Manual 7 2 Exploded View...

Page 16: ...nal S A S U used under license All trademarks referenced herein are the property of their respective owners 2012 Zodiac Pool Systems Inc H0394700 Rev A 1212 Zodiac Group Australia 219 Woodpark Road Sm...

Reviews: