Pelletherm V.4 LT
30
Figure 5.12. Exemplar hydraulic scheme for connecting a hot water pellet boiler from series
“Pelletherm V.4 LT” to a heating installation, mixing valve and a heat accumulator tank /
buffer.
Table 5.1 Description of the components on Figure 5.12.
No.
DESCRIPTION
1
Hot water boiler from series
“Pelletherm V.4 LT”
2
Safety valve
3
Boiler – domestic water
4
Return valve
5
Circulations pump 1
6
Safety valve
7
Opened or closed expansion
tank
8
Ball valve
9
3 way mixing valve
10
Circulations pump 2
The exemplar hydraulic scheme is only informative and can not be practically
used as implemented hydraulic scheme.
The installation and warm tests completion of the system must be registered
in its warranty card, as well as in the pellet burner from series “GP xx sc” card.
It is mandatory to complete all fields of required information in the warranty
cards.
No.
DESCRIPTION
11
Ball valve
12
Water filter
13
Temperature valve TV
14
Return valve
15
Contact thermostat
16
Heat accumulator tank
17
Water supply vending machine
18
Filling and draining crane
22
Automatic air freeing device with
valve/flap
23
Safety valve
24
Return valve
Summary of Contents for PELLETHERM V.4 LT SERIES
Page 46: ...Pelletherm V 4 LT 46...
Page 48: ...Pelletherm V 4 LT 48...