Pelletherm V.4 LT
25
5.4.4.
INSTALLATION OF THE DIRECTING FIRE-CLAY BRICKS IN THE HEAT
EXCHANGER UNIT’S COMBUSTION CHAMBER.
The fire-clay bricks must be positioned in the heat exchanger’s combustion chamber. They
are provided together with the boiler’s delivery kit (during transportation of the system the
bricks are packed and positioned in the ash tray inside the boiler’s combustion chamber).
Figure 5.4.The fire-clay bricks are properly positioned in the combustion chamber of a hot
water pellet boiler from series “Pelletherm V.4 LT”.
5.4.5.
INSTALLATION/CHECK OF THE ASH CLEANING SECTION COVER CAP.
Figure 5.5. The cover cap for cleaning of the ash residues, positioned after the
second flue pass of a hot water boiler from series “Pelletherm V.4 LT”, is properly
positioned.
The proper positioning of the cover cap is significantly important for the
efficient and reliable operation of the boiler. Therefore after completing the
installation of the boiler the cover cap position must be checked and also after
every cleaning of the ash residues.
5.4.6.
INSTALLATION OF THE COVER-FLAP IN FRONT OF THE FLUE GAS
OUTLET.
The cover-flap must be mounted, as on one of its sides it must be positioned over the
specially welded locking elements and on its other side it must contact the boiler’s body wall.