MCBA FOR SPECIALISTS: 
INSTALLER, SERVICE ENGINEER

SAFETY STOP (ERROR MODE)

If a fault occurs while the appliance is running, the system locks and
the screen starts to flash. The first character is an E and the next two
characters give the code for this fault, as illustratedin the table below.

Table of error codes and how to resolve them

To unlock the system:
• Press  RESET on the screen.
• Contact your installer if the fault happens again.

Codes

Description of the fault

Resolution of the fault

Abnormal flame signal

- Check the wiring 

(short-circuit in the 24V wiring)

- Check the electrode/ replace the MCBA 

(water damage).

No flame signal after five attempts at firing the boiler

- Check the ignition cable, the electrode and the 
position of the electrode.
- Check that there is gas at the burner.

Persistent lock

- Press RESET

EPROM error

-If the problem persists after two RESET attempts,
replace the MCBA.

Max input, thermostat open or 24V fuse gone.

- Check the wiring and check the

24V fuse on the MCBA.

Internal error

- If the problem persists after two RESET attempts,
replace the MCBA.

T1 > 110°C

- Check the NTC wiring and replace if necessary.

T2 > 110°C

- Check the NTC wiring and replace if necessary.

T1 gradient too high

- Check that the pump is turning. If there is
no problem with the pump, drain the system.

No fan signal present

- If the fan is working:
• Check the fan control connection and the fan wiring 
• if the problem persists after 2 RESET attempts, replace the

fan 

• if the problem persists, replace the MCBA.

- If the fan is not working:
• Check that the fan 230V connection. If the problem persists,

replace the fan.

NTC 1 short-circuit 

- Check the connection and the NTC1 wiring
If the problem persists, replace the NTC1.

NTC 2 short-circuit 

- Check the connection and the NTC2 wiring
If the problem persists, replace the NTC2.

NTC 3 short-circuit 

- Check the connection and the NTC3 wiring
If the problem persists, replace the NTC3.

NTC 1 connection open

- Check the connection and the NTC1 wiring
If the problem persists, replace the NTC1.

NTC 2 connection open

- Check the connection and the NTC2 wiring
If the problem persists, replace the NTC2.

NTC 3 connection open

- Check the connection and the NTC3 wiring
If the problem persists, replace the NTC3.

Internal error

- If the problem persists after two RESET attempts,
replace the MCBA.

Error while reading the parameters

Press RESET. If the error persists, replace the MCBA.

Problem with the power supply to the fan

Check the MCBA power supply voltage. If it is OK, replace
the fan.

To

Summary of Contents for MCBA

Page 1: ...TC wiring and replace if necessary T1 gradient too high Check that the pump is turning If there is no problem with the pump drain the system No fan signal present If the fan is working Check the fan control connection and the fan wiring if the problem persists after 2 RESET attempts replace the fan if the problem persists replace the MCBA If the fan is not working Check that the fan 230V connectio...

Page 2: ... temperature STEP STEP STEP STEP Minimum central heating temperature when using an outdoor sensor STEP Minimum outdoor temperature adjust the heating curve STEP Maximum outdoor temperature adjust the heating curve STEP Frost protection temperature STEP Correction based on the outdoor temperature STEP Blockage T 0 Disabled 90 01 01 90 60 0 20 15 00 00 STEP Key Display Description of parameters Fact...

Page 3: ...n speed in hot water mode rpm x 100 STEP 00 Min fan speed rpm x 100 STEP 15 Min fan speed rpm x 100 STEP 00 Fan speed at ignition rpm x 100 STEP 37 Heating pump time delay 0 10 sec minute 00 STEP Hot water pump time delay 10 2 10 sec minute 16 00 01 01 03 STEP Burner interlock hysteresis heating STEP Burner trigger hysteresis heating STEP Burner interlock hysteresis hot water STEP Burner trigger h...

Page 4: ...es from 0 room thermostat STEP 00 00 00 05 01 05 00 Key Display Description of the parameters Factory setting 1st digit Hot water circulator pump 1 2nd digit tank with NTC3 sensor 2 STEP Manual fan speed 01 modulation 12 01 11 00 60 30 01 00 STEP 1st digit PWM pump operating speed 2nd digit PWM pump speed during time delay STEP Holding temperature STEP Maximum temperature for the heating circuit o...

Page 5: ...e of increase in the hot water temperature in C s STEP Heating circuit outlet temperature AM3 11 4 way valve STEP Press STEP until the system displays the information you need The point located behind the first position flashes to indicate that the boiler is in INFO mode Key Display Description of parameters Key Display STEP STORE MODE STEP or Press STEP once and the system displays C in position ...

Page 6: ...er at the time of the error See the table on page 16 STEP Start temperature T1 at the time of the error MODE Return temperature T2 at the time of the error STEP Hot water temperature T3 at the time of the error STEP Outdoor temperature T4 at the time of the error STEP Key Display Key Display Description of parameters MODE No communication Communication between the boiler module and the optional co...

Page 7: ...A1000 B08 Fill set Ø 1 2 55426018 B09 Type A high level turbulators 507F2009 B10 Type B low level turbulators 507F2010 No Setting and electrical accessories C01 MCBA 537D8016 C02 Transformer 547D3021 C03 NTC Duplo NTC1 NTC2 5476G002 C04 NTC Single NTC3 5476G003 C05 Module AM3 11 10800080 C06 Module AM3 2 10800060 C07 Full control panel 24614133 C08 Display 537D3020 C09 Display case 537D3023 C10 Pr...

Page 8: ...iciency Gas pressure SERVICE NOTES Service date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min lo...

Page 9: ...ice date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min load CO2 max load Gas Propane Comments Name and signature Flue gas T Efficiency Gas pressure Service date CO2 min load CO2 max load Gas Propane Comments Na...

Page 10: ......

Page 11: ...com excellence in hot water www acv world com ARGENTINA TECNOPRACTICA ALFEREZ BOUCHARD 4857 1605 CARAPACHAY BUENOS AIRES TEL 54 11 47 65 33 35 FAX 54 11 47 65 43 07 E MAIL jchas tecnopractica com AUSTRALIA HUNT HEATING PTY LTD 10 GARDEN BOULEVARD 3172 VICTORIA AUSTRALIA TEL 61 3 9558 7077 FAX 61 3 9558 7027 E MAIL enquiries huntheat com au BRAZIL SIMETAL INDUSTRIA E COMERCIO DE FERRAMENTAS LTDA RU...

Reviews: