Pelletherm V.4 LT
26
This cover-flap is used to direct the flue gasses from the second to the third
pass of the boiler and also in case of emergency situations (for example if
high flue gas pressure inside the boiler occurs) it should be opened, in order
to decrease the pressure pulsations.
The cover-flap is subjected to thermal loads, therefore it symmetrically
manufactured. It is recommended to turn the cover-flap on every two to three
weeks of operation.
Figure 5.6. The directing cover-flap is dismounted and the boiler’s flue gas outlet
section is visible.
Figure 5.7. Directing cover flap – mounting and correct position.
The directing cover-flap is
positioned on the boiler’s
body side, before its final
positioning
The directing cover-flap is
positioned correctly
Hook for easy manipulation
of the directing cover-flap
Profile with a sealant rope
Summary of Contents for PELLETHERM V.4 LT SERIES
Page 46: ...Pelletherm V 4 LT 46...
Page 48: ...Pelletherm V 4 LT 48...