background image

SİRİUS

PREMIX 

CONDESING 

BOILER 

BOILER INSTALLATION AND USER’S MANUAL 

Read carefully before operat ng the appl ance

Summary of Contents for Sirius ErP PM 24

Page 1: ...SİRİUS PREMIX CONDESING BOILER BOILERINSTALLATIONANDUSER SMANUAL Read carefully before operat ng the appl ance ...

Page 2: ...ING THE BOILER5 6 SWITCHING OFF THE BOILER6 7 MAINTENANCE OF THE BOILER6 8 INSTALLATION INSTRUCTIONS6 9 DIMENSIONS OF THE BOILER7 10 CONNECTING THE FLUE8 11 ELECTRIC CONNECTION9 12 ELECTRIC SCHEME AND ROOM THERMOSTAT10 13 ERROR CODES 4IOS AND ANDROID ALL VERSIONS11 14 TECHNICAL DATA12 3 3 3 4 5 6 6 6 7 8 9 10 11 12 ...

Page 3: ...ler indicated in the data plate d Ensure that both central hea ng system and domes c hot water distribu on pipes are cleaned properly before the installa on and connec on to the boiler The manufacturer is not responsible of any damages arising from the dirt and small par cles le inside the piping and such failures and damages are out of warranty claim e The commissioning of the boiler must be perf...

Page 4: ... bu ons with figure With summer mode pump an blocking safety and an frost protec on func ons are ac ve b When the appliance is in winter mode the display shows and signs To adjust the desired central hea ng temperature use bu ons with figure To adjust the desired domes c hot water temperature use bu ons with figure With winter mode pump an blocking safety and an frost protec on func ons are ac ve WAR...

Page 5: ...ay 5 FILLING THE BOILER Filling water is supplied through the filling valve located in the bo om of the boiler Figure 3 When the boiler is cold the installa on should be filled such that the manometer located in the front of the boiler Figure 2 indicates a water pressure between 1 1 5 bar When the pressure drops to the cri cal level the appliance shuts off automa cally Figure 2 Figure 3 A Central hea...

Page 6: ...vice Donotcleanexternalsurfacesofyourappliancewithdetergentorchemicalmaterials Check your installa on before making connec ons to the boiler and ensure that the installa on pipesarefreefromdirtoranypar cles The life me of wall hung combina on boilers set by the Ministry of Science Industry and Trade is 15 years According to the relevant codesthemanufacturingcompaniesundertake to maintain and provi...

Page 7: ...he category available in the loca on where it will be used and the supplied gas pressure as well as the gas installa on isinconformitywithdataplate Figure 5 Condensate syphon hose outlet Central hea ng flow connec on Domes c hot water outlet connec on Gas connec on Domes c hot water inlet connec on Central hea ng return connec on 9 DIMENSIONS OF THE BOILER DimensionsoftheboileraregiveninFigure6 Fig...

Page 8: ...vesandroofcoverings b Minimum ver cal distance above the ground should be 0 3 m and in places where there isanimpactrisktheflueterminalmustbecoveredwithawirenet c When the flue terminal is extended off the wall it must extend minimum 18 cm outside thewall d Horizontallyconnectedflueconnec onsmustbeinstalledwith2 upwardslope e Where the appliance is installed to penthouses flue terminal should be minimu...

Page 9: ...CONNECTION The appliance must be connected to a power supply line with an efficient earth connec on The appliance must be connected to 220 230 V single phase power supply line with efficient earth connec onthrough2A Automa ccircuitbreaker ...

Page 10: ...horised service agency Such room thermostats may provide internet connec on and remote access may be made If required you may control the appliancethroughacomputerorsmartphonesandtabletsthatproviderequiredfeatures OPENTHETM REMOTE CONTROL OPTIONAL The remote control is designed for temperature management of any type environment Through this communica on protocol all func ons of the boiler can be c...

Page 11: ... Figure 13 In suchcaseiftheerrordoesnotdisappeara erperformingtheindicatedac ontheclosestauthorised servicemustbecalledtofixtheerroroftheappliance Figure 13 DESCRIPTION OF ERROR REQUIRED ACTION ERROR CODE No fire L H failure Ionisa on failure Safety thermostat failure Flue gas thermostat failure Low water pressure failure Central hea ng flow sensor failure Domes c hot water sensor failure Central hea...

Page 12: ...quency Power consump on Electric system protec on grade Connec ons to installa on Gas connec on Central hea ng circuit flow return HDW inlet outlet General specifica ons Sound power Flue diameter Ø Dimensions Height x Widt x Depth without package Dimensions Height x Widt x Depth without package with package Weight without package Weight with package G20 20 C13 C33 C43 C52 C82 B23 B33 I2H G20 20 mbar...

Page 13: ...13 Pump opera ng field 15 5 Discharge head capacity Power capacity ...

Page 14: ...5 65 Discharge head capacity Power Capacity Thisdocumentisissuedtoprovideinforma onabouttheappliance THERMEX in order to develop improve its products preserves the right to modify instruc on and user smanualwithoutpriorno ce ...

Page 15: ...Dear Customer Thank you for choosing a Thermex product www thermex com tr 0850 775 05 15 15 ...

Page 16: ...www thermex com tr ...

Reviews: