background image

801314UK - G4 Boiling chilled commercial installation instructions - June 2016 -  V2.04 

Page 25 of 28

End of life disposal

The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of 

separately to any other household waste.
Within each of the European Union member countries, provisions have been made for collection 

and recycling of unwanted electrical and electronic equipment. In order to help preserve our 

environment we ask that you dispose of this product correctly. Please contact Zip Customer 

Service on 0345 6 005 005 for advice.

Warranty

Certain warranties may be implied by law into your contract with Zip. The  warranty provided below is  

additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law.

Zip Heaters (UK) warrants that, should the hot tank fail within five years of installation subject to satisfactory 

maintenance and registration of the product, or any part fail within two years of installation, the part will be  

repaired or replaced free of charge by Zip, its distributor or service provider, (except as set out below),  

provided the appliance is installed and used strictly in accordance with the instructions supplied, and that 

failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or 

repair by any party not expressly nominated by Zip.

No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip  

service provider or the cost of removal, cartage and re-installation of any component of the appliance if it 

needs to be returned for repair to Zip or its distributor.

This warranty does not cover damage resulting from non-operation of the appliance, the use of non authorised 

parts or consequential damage to any other goods, furnishings or property.

No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary 

according to water quality and the rate of water consumption.

Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which 

cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip 

under the laws applicable.

Furthermore this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled 

to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the 

appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an 

equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the  

appliance.
HydroTap

®

G4 residential models are designed specifically for use in a domestic environment and 

inappropriate installations such as in a commercial location will invalidate the warranty.

Registering your purchase.
Registering your Zip installation on the Zip website may help to establish date of installation should it become 

necessary to service the appliance under terms of the Zip warranty. To register your installation go to  

www.zipwater.com/uk and look under the heading “Warranty”.

Summary of Contents for HydroTap G4 Series

Page 1: ...June 2016 V2 04 Page 1 of 28 Zip HydroTap G4 Installation instructions Affix model number label here 801314UK Filtered boiling and chilled drinking water for commercial kitchens and tea rooms VENTILAT...

Page 2: ...stomer s needs Classic HydroTap G4 range Arc Cube range Elite range All in One range Mixer range These standalone taps are directly compatible with the G4 Command CentreTM The All in One tap may be us...

Page 3: ...equired Section 2 Booster installation 2 1 Booster specifications and descriptions 13 2 2 Installation procedure 14 2 3 Booster installation 14 2 4 Braided hose connections 15 Section 3 Filter softene...

Page 4: ...supporting the Command CentreTM is adequate for its total weight when full of water Before commissioning Check the system has been installed correctly Check all plumbing fittings have been tightened...

Page 5: ...the water The boiling and chilled models will dispense boiling water factory set to 98 C chilled water factory set to 5 9 C These units are NOT designed to be used as sanitary fixtures The Zip HydroTa...

Page 6: ...or boiling water droplets may discharge through a vent outlet on the tap If the tap is not installed using the font ensure the tap body is located so the tap outlet safely dispenses into the sink bowl...

Page 7: ...rranty coverage As the installer it is your responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The HydroTap G4 is rated for 230V 50Hz...

Page 8: ...allation instructions A potable water supply connection with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock...

Page 9: ...red with booster 240 175 yes 2x13A 2 20 2 20 450 x 470 x 335 28 Min Max water supply pressure HydroTaps and Mains All in One taps 0 17 MPa 1 7 bar 0 7 MPa 7 bar Mixer taps and Vented All in One taps 0...

Page 10: ...for the booster Both the Command CentreTM and booster must be installed in accordance with IEE regulations See Technical specification page 9 for power ratings Note Check all cable and hose lengths ag...

Page 11: ...let vent B Air inlet vent 1 1 Preferred ventilation arrangement shown below The ducted vent kit supplied with the Command CentreTM exhausting through the kick space should be used to provide adequate...

Page 12: ...nd CentreTM B Fan kit fitted to cupboard door position B1 or side position B2 and without kick space duct fitted to the Command CentreTM For dual exhaust fan cut out dimensions see the instructions pr...

Page 13: ...m Mount base horizontally 2 1 Product description The booster system is a compact electronically controlled auxiliary water heater It is intended to provide pre heating of water before it enters the Z...

Page 14: ...ter outlet hose must be thermally insulated with the insulation provided Tilt forward Lift up Release Note Remove the wall mounting chassis from the rear of the booster for wall mounting Take care not...

Page 15: ...oses from the BYPASS OUT fitting on the Command CentreTM to the water inlet of the booster blue cap and from the outlet of the booster red cap to the BYPASS IN fitting on the Command CentreTM Avoid ex...

Page 16: ...etroleum products to lubricate the o rings Install cartridge with a quarter turn anticlockwise until cartridge comes to a complete stop Cartridge installation is complete Note The following instructio...

Page 17: ...g in place Section 4 Command CentreTM installation If no external filter is installed select position A A Rotate 90 only 1 2 3 4 4 1 External bypass valve The diverter bypass valve allows the user to...

Page 18: ...e assembly is fitted in place if the booster and or external filter are not used Not required for HydroTap G4 models Note Ambient mains water braided hose length is 750mm Electrical power cable length...

Page 19: ...pipes must be cut to size They must have a constant fall back to the Command CentreTM Clearance envelope 535mm 535mm CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Op...

Page 20: ...ble length is 3m nom Position the Command CentreTM according to the hose and cable lengths supplied Note All silicon tubes plastic pipes must be cut to size They must have a constant fall back to the...

Page 21: ...ngth is 3m nom Position the Command CentreTM according to the hose and cable lengths supplied Note All silicon tubes plastic pipes must be cut to size They must have a constant fall back to the Comman...

Page 22: ...cket or container not supplied Note At first commissioning the system will select the filter flush screen automatically 5 2 Filter flush Prepare filter flush as per instructions and press START Boilin...

Page 23: ...ress the MENU button for main menu Press the Install button Press the Boost button In the next screen select YES to enable the booster Before connecting the power to the booster water must be run thro...

Page 24: ...Sensor Closed Internal fault Check ventilation call Zip Service Condenser Sensor Open Internal fault Check ventilation call Zip service Heater Fuse Driver Fault Internal fault Call Zip Service Heater...

Page 25: ...ce provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its distributor This warranty does not cover damage res...

Page 26: ...Page 26 of 28 801314UK G4 Boiling chilled commercial installation instructions June 2016 V2 04 Notes...

Page 27: ...801314UK G4 Boiling chilled commercial installation instructions June 2016 V2 04 Page 27 of 28 Notes...

Page 28: ...s of Zip Heaters Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859...

Reviews: