Operation and settings 35
4.3.9 The menu "INSTALLATION"
Contents: In menu "INSTALLATION", values depending on the installation have to be put in once prior to
the first travel.
Figure 4.15 Menu structure
ANL
Selection of the type of installation
-
Elevator
(with counterweight),
-running gear,
-lifting gear (resp. elevator without counterweight).
N_NENN
Input of the nominal motor speed according to the indication on the motor identification plate.
V_NENN
Input of the nominal speed of the cab at the nominal motor speed N_NENN.
When selecting this parameter, there is the inquiry from the control device whether
V_NENN is to be put in directly or whether it has to be calculated by means of further
installation data. In case of the installation type "ELEVATOR", the suspension, the
gear ratio as well as the friction wheel diameter are inquired for calculation.
A value can be set by means of the arrow keys and the text can be scrolled by means
of the key P. With this conversational inquiry it is not possible to scroll back.
GEBER
Selection of the type of the encoder installed at the motor.
- ET 3R-1024
- ET 3F-64
- ET 3F-48
- EXTERNAL
By using an encoder of any other manufacturers with 1024 pulses per revolution you can also use
the setting ET3R-1024. You have only to use the parameter EXTERNAL by an encoder with an
other number of pulses per revolution.
>Installation type
N_NENN
INSTALLATION
************************
ANL
ELEVATOR
1380 min-1
>Nominal speed of motor
V_NENN
1.20 m/s
>Nominal travel speed
AUTO
OFF
>Automatic parameter
.
MO_DR
LEFT
>Direction of motor
GEBER
ET3R-1024
>Encoder type
A_MAX
3.5m/s2
>Max. deceleration
S_ABH
ON
>Distance dependency
T_SIG
>
0.00 s
Direct ?
[YES] [NO]
V_NENN
1.20 m/s
> 1.20 m/s
Suspension 1:1
P
P
P
Gear ratio 1:38
D_wheel 650 mm
P
Gear ratio 1:38
Part1
Part2