36 Operation and settings
In case of the setting "EXTERNAL", the parameter G_AUF with which it is possible to set any
transmitter resolution ranging from 64 to 1024 pulses/revolution is faded in after this
parameter.
AUTO
Automatic parameter pre-assignment:
-
OFF
no effect
- ON
The parameters in /TRAVELLING, /ACCELERATING and / DECELERATING are
preassigned once according to the type of installation, nominal speed and nominal
revolution. After the pre-assignment, AUTO is again at "OFF".
MO_DR
Changing the motor direction.
S_ABH
Selection how the arch travel is to be driven:
-
ON
In case of deceleration transfers from V3 -> V1 and V2 -> V1, the arch travel is driven
dependent on the distance and using the optimum time possible.
- OFF The arch travel is driven time dependent at all speed transfers.
A_MAX
Input of the maximum deceleration in case the controller release "RF" is switched off during
running.
At a value of 3.5 m/s
2
(factory setting), the power unit is immediately switched currentless and
the output relay "mechanical brake - MB" and "controller active - RB" are released without
delay.
T_SIG
In case of controls where the signal operation time is not to be neglected, the speed
dependent distance errors are automatically compensated by the control device when this
time is put in here.
G_AUF 1024
Encoder resolution