A1 Technical data
Denotation of controller
ZETADYN 1DV0xx
16
25
40
60
80
90
Nominal mains voltage
V
3~ 230 / 400 / 500 (ab15/-10%)
Mains frequency
Hz
50/60 (automatic change-over)
Nomiminal current
A
16
25
40
60
80
90
Maximum operation current for 5 sec.
4* Rated current
operational ambiant temperature
°C
0 bis 45
storing and transportation temperature
°C
-20 bis 60
location
NN
< 1000 m at rated current
Protective system DIN 40050,IEC 144
IP00, VBG4 is met
aggressive media, dust, fog, water or moisture are not
allowed to penetrate into the device
The controller corresponds the safety class 1,
DIN VDE 0558, Teil 1, Pkt. 5.4.3.1.1
Relative humidity of air
%
90 , not bedewed
Weight
kg
9.5
9.5
9.5
11.5
12.5
13
Dimensions H
mm
290
306
W
350
350
L
230
230
Mains fuses
"gL" according to the nominal motor current
terminal cross section
mm
2
10
10
16
16
35
35
Others:
Mains "L1 L2 L3"
The mains trafos are only partly short-circuit proof according to VDE
0551.
Control inputs
Current consumption: typ. 15 mA/input.
Voltage between "U0" and "GND": unstable 20 to 24 V DC
Relay outputs
Contact current-carrying capacity: 230 V AC/2A at cos phl > 0.4
Speed transmitter
A encoder with two square wave signals where the phase is shifted
by 90° is required. As standard, a resolution of 1024
pulses/revolution is recommended. It is possible to connect
encoders with a resolution ranging from 64 to 1024 pulses.
"ET1" +15V
"ET2" track A
"ET3" track B
"ET4" GND
"ET5" -15V
Total current consumption of the encoder: max. 250 mA
Current consumption per track: typ. +7 mA /-1 mA
Motor posistor connection
"P1-P2"
Temperature monitoring of the motor according to DIN 44 081.
-Electrolytically separated by means of an opto-coupler.
-In case of a resistor of higher than 2.5 kOhm at "P1 P2", a trouble
occurs.
Thermal contact on the upper
part of the power stage
This thermal contact switches the control device off when a heat
sink temperature of 80 ° C is achieved
Only controller 1DV080 and
1DV090
fan terminal "11-12"
Independent from the nominal voltage, the connection voltage is
230V 50/60Hz.
A thermal contact switches the fan on at a heat sink temperature of
max. 55° C and switches it off at a temperature of min. 35° C
EMC & rfi suppression
The control devices are indifferent to trouble and tested according to IEC 801-4.
As standard, commutation throttles are incorporated in the control devices.
By using the radio interference filter (FEFUS) the radio interference level B
is attained (EN 55011)