Position Mode (Position Mode [pp]
Position Mode
Most controls write the mode to the ZAdyn4B shortly before start-up. This means that the operating
mode must be set in the control.
If the ZAdyn4B is operated in position mode, the shaft encoder must be connected to the same bus as
the ZAdyn4B.
The control system sends the required speed to the ZAdyn4B before every journey. If this cannot be
achieved, the ZAdyn4B will initiate a triangular speed pro
fi
le journey. The maximum speed must
therefore be entered in the control system.
9.2.1.8
Command- and Statusbits of the recorder
•
Position Mode [pp] C&S / Velocity Mode [pv] C&S
•
C = Command = command from the control to the frequency inverter
•
S = Status = Status of the ZAdyn4B as reaction to a prior command from the control system
Status- / Commandbit
Designation
Remarks
CSwO
Command Switch On
CEVo
Command Enable Voltage
CQSt
Command Quick Stop
CEOp
Command Enable Operation
CFaR
Command Fault Reset
CNSp
Command New Setpoint
only active in position mode
CHlt
Command Halt
SRSO
Status Ready to Switch On
SSdO
Status Switched On
SOpE
Status Operation Enabled
SVoE
Status Voltage Enabled
SQSt
Status Quick Stop
SSOD
Status Switch On Disabled
STaR
Status Target Reached
SS=0
Status Speed = 0
only active in velocity mode
SSpA
Status Setpoint Acknowledge
only active in position mode
SFlt
Status Fault
SWrn
Status Warning
Original operating instructions
ZAdyn4B 110-180
Serial communication
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
66/200