X-MON
+24V_
CO
CO1
CO2
K1
K2
(1)
(2)
(3)
Connection internal contactor monitoring
–
series circuit
1
Parameter "Monitoring/CO=CO1"
()
terminal designation of connector
X-MON
+24V_
CO
CO1
CO2
K1
K2
(1)
(2)
(3)
Connection internal contactor monitoring
–
separate
1
Parameter "Monitoring/CO=CO1&CO2"
()
terminal designation of connector
CAUTION!
Attention!
The internal 24 V power supply is provided solely for the contactor monitoring. Switching consumer
load with this voltage is prohibited!
5.20
Brakes
5.20.1
Brake release monitoring (X-BR)
Information
The brake release monitoring serves as monitoring for redundancy and the operation status of the
brakes.
It is recommended that the brake air monitor be connected to the ZAdyn4B for optimum start-up and
stopping.
When the lock function is activated, the brake release monitoring ful
fi
ls the requirements for self-
monitoring according to chapter 5.6.6 EN81-20 for ascending car overspeed protection means and
chapter 5.6.7 for protection against unintended car movement.
Monitoring voltage
+24 VDC / 8 mA
Contact type
Normally open contact (NO) or nor-
mally closed contact (NC)
Number of inputs
4
Clamping range
max. 1,5 mm
²
Current consumption at 24 V
typ. 8 mA
The contactor monitoring can be activated/deactivated in the menu
Monitoring
.
Monitoring
|
-
"
BR
1*NC
|
-
"
3*NC
Brake control (BR1..BR4)
The lock function on the ZAdyn is engaged by activating the
“
LOCK_X=On
”
parameter in the
Monitor-
ing
menu.
Monitoring
|
-
"
LOCK_X
Off
|
-
"
On
Lock inverter
Activation of the parameter ensures that the ZAdyn locks upon detection of a faulty brake circuit.
The ZAdyn lock can only be released by setting the
“
Monitors / UNLOCK = On
”
parameter.
Original operating instructions
ZAdyn4B 110-180
Electrical installation
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB