15.9
Operation with a 3-phase 230 VAC power supply
The ZAdyn4B can be operated with a 3~ 230 VAC power supply.
For this purpose, it is only necessary to adapt various monitoring functions to the lower power supply.
Power component
|
-
"
UDC_N
325
V
|
-
"
325
Nominal DC voltage
In the menu
"Power section"
con
fi
gure the parameter
"UDC_N=325 V"
Power component
|
-
"
UDC_MIN 250
V
|
-
"
250
Min. DC voltage
In the menu
"Power section"
con
fi
gure the parameter
"UDC_MIN=250 V"
Power component
|
-
"
UDC_MAX 760
V
|
-
"
760
Max. DC voltage
In the menu
"Power section"
con
fi
gure the parameter
"UDC_MAX=760 V"
Power component
|
-
"
U_BC
650
V
|
-
"
650
BC intervention voltage
In the menu
"Power section"
con
fi
gure the parameter
"U_BC=650 V"
Original operating instructions
ZAdyn4B 110-180
Special functions
R-TBA15_01-GB 2014 Index 005
Part.-No. 00163453-GB
174/200