14
Energy saving
14.1
ZAdyn4B standby function
To save energy at standstill, the ZAdyn4B can be switched to stand-by mode. Internal components of
the ZAdyn4B are switched off in stand-by mode. This means that the ZAdyn4B has a much lower
power loss at standstill. There are two stand-by modes in the ZAdyn4B: Standby 1 and Standby 2
Standby 1:
In Standby 1 mode, the rotary encoder, monitoring functions and the output relay remain
active,
Standby 2:
In Standby 2 mode, the rotary encoder is switched off, the monitoring functions are not active
and all relays are switched off, including the fault indication relay.
14.1.1
Activate Standby 1 or Standby 2 mode
Information
It is only possible to switch to Standby 1 or Standby 2 mode when the controller enable (input CE) is
switched off.
Set digital input in the
Control
menu to
STANDBY1
or
STANDBY2
.
Control system
|
-
"
f_I08
STANDBY1
|
-
"
STANDBY1
Function of I_08
5 ms after deactivation of the digital STANDBY1 input, the ZAdyn4B is ready for operation again (see
diagram).
STANDBY 1
ST
1
2
5 ms
RF
Function of Standby 1 mode for ZAdyn4B
1
STANDBY1 input is activated
2
STANDBY1 input is activated
RF
Controller enable
STANDBY1
Input with STANDBY 1 function
ST
Fault