168
ELECTRIC INSTALLATION
E602
ELECTRIC SYSTEM
Nominal voltage
(minus (-) pole grounded)
12 V
Battery (1)
12V/155Ah
12 V
12V/165Ah*
12 V
Alternator with a built-in voltage
controller (2)
14V / 100A
Starter motor with a reducer (3)
12V / 3 kW
BASIC SERVICE INFORMATION
The battery must always be connected with the “minus” pole to the ground and with
the “plus” pole to the alternator. If the battery is connected the other way round, it will
destroy the whole semiconductor equipment of the alternator. When starting the
tractor with the use of an auxiliary battery, do not forget to connect the terminals
“plus” to “plus” and “minus” to “minus”. If you replace a part of the charging circuit,
disconnect the battery from the tractor ground (-) with the battery disconnector. This
way you will avoid accidental short-circuits on the terminals.
In case of any handling or repair of the started motor the minus pole of the
battery must be disconnected and all the shifting levers, incl. the PTO shifting
lever, must be in the neutral position (do not forget to check whether the
locked PTO switches on the right cabin pillar are off as well to prevent spon-
taneous start and endangering of the service person's life).
It is forbidden to start the engine by short-circuiting the starter motor termi-
nals.
Only start the tractor from the driver’s seat!
Summary of Contents for FORTERRA HSX 100 2014
Page 1: ......
Page 6: ...7 LOCATION OF SERIAL NUMBERS XH154...
Page 42: ...43 NOTES...
Page 43: ...44 ACQUAINTANCE WITH THE TRACTOR FH12N010...
Page 97: ...98 NOTES...
Page 129: ...130 NOTES...
Page 141: ...142 NOTES...
Page 149: ...150 NOTES...
Page 165: ...166 NOTES...
Page 217: ...218 NOTES...
Page 225: ...226 NOTES...
Page 241: ...242 NOTES...
Page 250: ......