125
HYDRAULIC SYSTEM
FH12N045 C411a
FH12N046
OUTER HYDRAULIC CIRCUIT
The outer circuit supplies pressurized oil
to hydraulic implements connected to the
outer outlets of the hydraulic system ter-
minated with quick-couplers.
The sockets of the rear (A) as well as
front (B) quick-couplers have the inner
diameter of 12.5 mm and comply with the
international ISO 5675 standard.
CONNECTING AND DISCONNECTING
QUICK-COUPLERS
When connecting and discon-
necting the quick-couplers pay
increased attention with regard
to the residual oil that remains in
the socket or on the plug of the
quick-coupler.
For environmental reasons after
every disconnection of quick-
couplers this residual oil must be
removed with any textile materi-
al.
*QUICK-COUPLINGS WITH DRIP
COLLECTION
Optionally, a system of collection of re-
sidual oil drips with a tank can be in-
stalled.
Regularly check whether the tank is not
full; dispose of the oil in an environment-
friendly way.