DESCRIPTION OF THE DEVICE
Colibri 7
Operating and function controls
ZEISS
02/2017
423052-7344-001
13
Operating data
Operating area ............................................................................................................... Enclosed rooms
Protection class ......................................................................................................................................I
Ingress protection rating .................................................................................................................. IP 20
Electrical safety ........................................................... in compliance with DIN EN 61010-1 (IEC 61010-1)
.............................................................................................
and conforming to CSA and UL regulations
Overvoltage category ............................................................................................................................. II
Radio interference suppression ........................................................ in compliance with EN 55011 Class B
Noise immunity ............................................................................... in accordance with DIN EN 61326-1
Line voltage of controller module ..................................................................... 100 to 240 VAC (
±
10 %)
Line frequency ...................................................................................................................... 50 to 60 Hz
Power consumption of controller module ....................................................................................... 70 VA
Colibri 7 overall LED classification
........................... LED risk group 3 according to DIN EN 62471:2009
Solid-state light source Colibri 7, type RGB-UV ............. LED risk group 3 according to DIN EN 62471:2009
Solid-state light source Colibri 7, type RYB-UV .............. LED risk group 3 according to DIN EN 62471:2009
Solid-state light source Colibri 7, type R[G/Y]B-UV ........ LED risk group 3 according to DIN EN 62471:2009
Solid-state light source Colibri 7, type R[G/Y]CBV-UV .... LED risk group 3 according to DIN EN 62471:2009
2.4
Operating and function controls
2.4.1
Connection panel on the lamp
module
The following connectors are located on the lamp
module (Fig. 4):
1
Increment
connection socket
2
USB
connection socket
3
Remote
connection socket
4
Breakout
connection socket
5
Power
connection socket
6
CAN
connection socket
Fig. 4
Connection panel on the lamp
module