Care
9-5
CenterMax Operating Instructions
61211-1020202
Overview
The components requiring care are listed in the following. The time
intervals apply only if all installation site requirements have been met.
Care measures
Measuring table
The workpieces must have full contact with the measuring table. Any
hard particle below the workpiece may lead to inaccurate measure-
ments. Furthermore, the surface of the measuring table and the
workpiece may be damaged.
Object
Interval
Type of care
Measuring table
Every week or more fre-
quently
Vacuum cleaner,
cleaning agent
➤
page 9-5
Threaded holes in the
measuring table
Every week
Vacuum cleaner
➤
page 9-6
Probe elements
At least every week
Depending on the degree
of soiling:
–
cleaning agent.
–
Special solvent; e.g.
KOH for removing alu-
minum deposits
➤
page 9-6
Calibration sphere
Every week or more fre-
quently
Cleaning agent
➤
page 9-7
Adapter plate
As required
Fluff-free cloth; possibly
cleaning agent
➤
page 9-7
Probe head
As required
Dry or damp cloth
➤
page 9-7
Probe rack
Every month
Vacuum cleaner
clean with a cleaning
agent, if required
➤
page 9-8
Concertina cover
Every month
Vacuum cleaner
➤
page 9-8
Housing covers
Every month
Mild normal cleaning
agent
➤
page 9-8
Filter mat for ventilation
of the control cabinet
Every three months
Clean by beating and vac-
uum with a vacuum
cleaner;
replace the filter, if
required
➤
page 9-9
Filter for compressed air
As required
Change
➤
page 9-10
Summary of Contents for CenterMax
Page 1: ...Operating Instructions CenterMax Coordinate measuring machine for series production...
Page 9: ...61211 1020202 Operating Instructions Contents7 Appendix Application examples 1...
Page 10: ...61211 1020202 Operating Instructions Contents 8...
Page 14: ...Foreword 61211 1020202 Operating Instructions...
Page 26: ...1 12 Introduction 61211 1020202 CenterMax Operating Instructions...
Page 58: ...3 6 Technical data 61211 1020202 CenterMax Operating Instructions...
Page 64: ...4 6 Transport and installation 61211 1020202 CenterMax Operating Instructions...
Page 80: ...5 16 Preparations for start up 61211 1020202 CenterMax Operating Instructions...
Page 100: ...6 20 Start up 61211 1020202 CenterMax Operating Instructions...
Page 134: ...7 34 Measuring operation 61211 1020202 CenterMax Operating Instructions...
Page 144: ...8 10 Errors and faults 61211 1020202 CenterMax Operating Instructions...
Page 156: ...9 12 Maintenance and care 61211 1020202 CenterMax Operating Instructions...
Page 162: ...61211 1020202 Operating Instructions Glossary 2...
Page 164: ...61211 1020202 Operating Instructions Appendix 2...
Page 165: ......