![background image](http://html1.mh-extra.com/html/zehnder-pumpen/kompaktboy-doppel/kompaktboy-doppel_operating-manual_3324126081.webp)
Kompaktboy Double
en
English
81
5.7 Optional manual membrane pump
At the collecting tank near the ground, there are 2 threaded sockets Rp 1 ½“. The threaded
sockets are closed with red protective plugs. In order to connect a pipeline there, the tank
must be opened using a drill or hole saw.
1.
Z
Screw out the protective plug.
2.
Z
Using a drill or hole saw, drill out the closed
socket bottom (max
ඦ
40 mm).
3.
Z
Connect the draining line.
i
,QRUGHUWRIDFLOLWDWHUHSDLUZRUNVRQWKHPDQXDOPHPEUDQHSXPSDò³VKXWRႇYDOYH
should be installed in the venting line near the ground.
5.8 Installing the control
All electrical systems used must comply with the standard IEC 364 / VDE 0100, that
is sockets, for example, must have earth terminals.
7KHHOHFWULFDOFRQQHFWLRQPD\EHFDUULHGRXWE\DQHOHFWULFDOO\TXDOL¿HGSHUVRQ7KH
pertinent VDE regulation 0100 must be observed!
7KHHOHFWULFDOQHWZRUNWRZKLFKWKHSODQWLVFRQQHFWHGPXVWKDYHEHHQ¿WWHGZLWK
a highly sensitive FI protected switch IA <30 mA before the control, or to prevent a
failure of the control when the FI protected switch trips, one FI protected switch per
pump has to be installed between the control and pump. For installations in bath-
rooms and showers, the corresponding regulations of DIN VDE 0100 Part 701 have
to be observed.
Please observe the regulations of EN 12 056-4.
For AC power connection, external protection has to be carried out with circuit break-
ers of characteristic K, generally 3-pole mechanically locked. In this way, complete
supply isolation is ensured and 2-phase run excluded.
In dry rooms, all electrical devices such as controls, alarm transmitters and sockets
PXVWEHLQVWDOOHGÀRRGSURRI
Before every installation and disassembly of the pump or other work on the plant, it
must be disconnected from the mains supply.
The motor can overheat due to overload. In case of overheating, never touch the hot
surfaces on the motor.
When using an extension cable, it must meet the quality of the supplied connecting
cable.
Summary of Contents for KOMPAKTBOY DOPPEL
Page 21: ...Kompaktboy Doppel Deutsch 21 Einbaubeispiel zur Absch tzung des Platzbedarfs der Hebeanlage...
Page 44: ...Kompaktboy Doppel Deutsch 44 9 2 1 Abmessungen Kompakboy Doppel 1 1 und 1 5...
Page 45: ...Kompaktboy Doppel Deutsch 45 9 2 2 Abmessungen Kompakboy Doppel 3 0...
Page 46: ...Kompaktboy Doppel Deutsch 46 10 Ersatzteilliste...
Page 92: ...Kompaktboy Double en English 92 9 2 1 Dimensions of the Kompaktboy Double 1 1 and 1 5...
Page 93: ...Kompaktboy Double en English 93 9 2 2 Dimensions of the Kompaktboy Double 3 0...
Page 94: ...Kompaktboy Double en English 94 10 List of spare parts...
Page 140: ...Kompaktboy Double fr Fran ais 140 9 2 1 Dimensions Kompakboy Double 1 1 et 1 5...
Page 141: ...Kompaktboy Double fr Fran ais 141 9 2 2 Dimensions Kompakboy Double 3 0...
Page 142: ...Kompaktboy Double fr Fran ais 10 Liste de pi ces de rechange...