Kompaktboy Double
en
English
82
5.8.1 Installing the control
$ÀRRGSURRIDQGIUHHZDOODUHDRIDSSUR[[PPQHDUWKHOLIWLQJXQLWLVUHTXLUHGIRU
the installation of the pump control. The connecting cable of the pump is 3.50 m long. The
installation site of the control has to be selected accordingly. The control has to be installed
in such a way that the cable entries face downward.
The control must be installed in such a way that the blue pneumatic hose for the level
control can be laid rising steadily from the lifting unit to the connection at the switch box.
This is the only way to ensure proper functionality of the automatic control.
!
1.
Z
Transfer the hole pattern onto the wall.
2.
Z
Drill 4 holes, suck away and drive in dowels.
3.
Z
Open the control cover – while doing so, check to
see that no cable connections are loosened.
4.
Z
Using 4 screws, tighten the control.
5.
Z
Put on the control cover and screw down –
while doing so, check to see that no cables are
jammed.
With the electrical connection of the control, a disconnecting device should exist locally.
i
Summary of Contents for KOMPAKTBOY DOPPEL
Page 21: ...Kompaktboy Doppel Deutsch 21 Einbaubeispiel zur Absch tzung des Platzbedarfs der Hebeanlage...
Page 44: ...Kompaktboy Doppel Deutsch 44 9 2 1 Abmessungen Kompakboy Doppel 1 1 und 1 5...
Page 45: ...Kompaktboy Doppel Deutsch 45 9 2 2 Abmessungen Kompakboy Doppel 3 0...
Page 46: ...Kompaktboy Doppel Deutsch 46 10 Ersatzteilliste...
Page 92: ...Kompaktboy Double en English 92 9 2 1 Dimensions of the Kompaktboy Double 1 1 and 1 5...
Page 93: ...Kompaktboy Double en English 93 9 2 2 Dimensions of the Kompaktboy Double 3 0...
Page 94: ...Kompaktboy Double en English 94 10 List of spare parts...
Page 140: ...Kompaktboy Double fr Fran ais 140 9 2 1 Dimensions Kompakboy Double 1 1 et 1 5...
Page 141: ...Kompaktboy Double fr Fran ais 141 9 2 2 Dimensions Kompakboy Double 3 0...
Page 142: ...Kompaktboy Double fr Fran ais 10 Liste de pi ces de rechange...