User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
135/193
ID 903
Software CBC overcurrent protection
ID 904
Pack ID error
Restart the battery and wait for seconds. If the
problem is not resolved, please contact technical
support.
ID 928
Battery reversal
Check whether the wiring is correct and restart
the battery. If the problem is not resolved, please
contact technical support.
ID 929
Fusing failure
Restart the battery. If the problem is not resolved
or occurs frequently, please contact technical
support.
13.
Maintenance
Inverters generally do not require daily or routine maintenance. In any case, for proper long-term operation
of the inverter, make sure that the heatsink for cooling the inverter has enough space to ensure adequate
ventilation and that it is not obstructed by dust or other items.
Cleaning the inverter and battery module
Please clean the inverter with an air blower, a dry & soft cloth or a soft bristle brush. Do NOT clean the inverter
with water, corrosive chemicals, detergent, etc.
Cleaning the heatsink
In order to ensure the normal function and long service life of the product, it is necessary to ensure that there
is enough air flow space around the radiator at the rear of the product, and there is no material around the
radiator that obstructs the air flow, such as dust or snow, must be removed. Clean the radiator with
compressed air, a soft cloth, or a soft brush. Do not use water, corrosive chemicals, cleaning agents, or strong
detergents to clean the heat sink.
13.1.
Store and charge the battery module
Battery module storage requirements:
1.
Environment temperature
:
-
10℃~
50
℃
,
Recommended storage temperature
:
25℃~35℃.
2.
Storage relative humidity range
:
5%~70%.
3.
Store in a dry, clean, and ventilated environment, away from direct sunlight.
4.
If the battery module is stored for a long time, replenish the power supply periodically. Battery module
power supply requirements: the charging current is less than or equal to 7A, and the battery module needs