User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
16/193
2.
Requirement for installation and maintenance
Before installation, please read this manual carefully and make sure you fully understand its contents. The 1PH
HYD3000-HYD6000-ZP1 inverter strictly complies with the safety, design and testing regulations provided for by
the national standards.
During installation, operation and maintenance, operators must carefully observe the local safety standards.
Improper use may result in electrical shock and harm and damage to persons, the equipment and its components.
Contact the nearest authorised service centre for any repairs or maintenance. Contact your distributor for
information on the nearest authorised service centre. DO NOT carry out repairs yourself, as this may result in
injury or damage.
Ensure that the operator has the necessary skills and training to operate the equipment. Personnel responsible
for the use and maintenance of the equipment must be qualified and capable of performing the activities
described, and must also have appropriate knowledge on how to correctly interpret the contents of this manual.
For safety reasons, this inverter can only be installed by a qualified electrician with the necessary training and/or
skills and knowledge. Zucchetti Centro Sistemi S.p.A. declines all responsibility for damage to property or personal
injury caused by incorrect use of the device.
Install and start the inverter according to the following instructions. Place the inverter on suitable load-bearing
supports with sufficient load capacity (such as walls or racks) and make sure that the inverter is positioned
vertically. Choose a suitable location for the installation of the electrical equipment. Make sure there is sufficient
space for heat dispersion and to accommodate future maintenance. Maintain adequate ventilation and ensure that
there is enough air circulation for cooling.
If you have problems with the packaging that could damage the inverter or if you find any visible damage,
immediately notify the transport company. If necessary, request assistance from an installer of photovoltaic
systems or from Zucchetti Centro Sistemi SpA. Transport of the equipment, especially by road, must be carried
out with vehicles suitable to protect the components (in particular, electronic components) against violent
knocks, humidity, vibrations, etc.
2.1.
Safety Notes
•
Electrical installation and maintenance of the system must be carried out by qualified and certified
electricians in compliance with national regulations.
•
The 1PH HYD3000-HYD6000-ZP1 inverter may only be installed by qualified PERSONNEL and by those who
have the appropriate certification, as required by the local authorities.
•
DO NOT place materials explosives or flammable (e.g. gasoline, kerosene, oil, wood, cotton or similar) near
the batteries or the 1PH HYD3000-HYD6000-ZP1 inverter.
•
Before maintenance, disconnect the AC connection, then the batteries and the photovoltaic system
(PV1&PV2), wait at least 5 minutes (capacitor discharge time) so as to prevent electric shock.
•
The 1PH HYD3000-HYD6000-ZP1 inverter must be completely disconnected (BAT, PV & AC) during
maintenance.