User’s Manual 1PH HYD3000-HYD6000-ZP1
Rev. 1.0 01/09/2023
Identification: MD-AL-GI-00
Rev. 1.1 of 27/01/2023 - Application: GID
87/193
Three-phase DTSU meter configuration on exchange and production
To view the device in read mode on the exchange you need to enter the settings menu, as indicated below:
4.
Press
SET
the inscription will appear
CODE
5.
Press
SET
, the inscription will appear “600”:
6.
Write the figure “701”:
a.
From the first screen where the number "600" appears, press the " key once to enter the
number "601".
b.
Press "SET" twice to move the cursor to the left to highlight "601";
c.
Press the" " key once more until you enter the number "701" (701 is the access code to the
settings).
Note:
In case of error press "ESC" and then again "SET" to reset the required code.
3.
Confirm by pressing
SET
until you enter the settings menu.
4.
Enter the following menus and set the parameters indicated:
d.
CT
:
i.
Press
SET
to enter the menu
ii.
Write“40”:
1.
From the first screen where the number "1" appears, press" " repeatedly until the number
"10" appears.
2.
Press
"SET"
once to move the cursor to the left to highlight "10”
3.
Press the button ”→” several times until you enter the number "40"
Note:
In the event of an error, press "SET" until the number of thousands is highlighted and then
press " " until only the number "1" appears;
at this point repeat the procedure described above.