H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010
Fax +49 241 91050138 • [email protected] • www.zander-aachen.de
17
Operating manual ZX09/20/21-Series
ZX09A
Digital Output
01 02 03 04
T/R
Lk
Digital Input
01 02 03 04 05 06 07 08 09 10
1+ 1- 2+ 2- Ck+ Ck- D+ D-
RS-485
SSI
Analog Input
20mA 10V A+ 0 V
RUN
OC
1 2 3
Fig. 9: Connection terminals ZX09A
Fig. 10: Connection terminals ZX09B / ZX09C / ZX09D / ZX09E
U+
Power Supply
L+ M M
Digital Output
01 02 03 04
T/R
Lk
Digital Input
01 02 A
1
+ 0V A
2
+ 0V A
3
+ 0V A
4
+ 0V
Switchable Analog Input
10 V
A
5
+ 0V
RUN
OC
1234
Analog Input
A
6
+ 0V
20 mA
10 V
20 mA
Only ZX09D/E
SSI
Ck+ Ck– D+ D-
2- 2+ 1- 1+
RS-485
Only ZX09D/E
ZX09B/C/D/E
Power Supply
L+ M M U+