FSDI-DCK-1X User Instructions
DOC-USR-0131-03
______________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
44
(3)
Set the
Remote IP
field to the IP address of your FSDI-DCK-1X. This can be found using ZFinder or as
the URL of the web browser with the user interface open.
(4)
Set the
TCP Port
to
1000
. This value must match the Camera 1 (
VISCA) Control TCP Port
value
listed in the Camera tab of the FSDI-DCK-1X user interface.
(5)
Assign a
COM Port
that is not currently in use on your system using the dropdown menu.
(6)
Click the
Connect
button. The application will minimize. Do not close this application while your
camera control is in use.
The COM port selected will now redirect data to the FSDI-DCK-1X.
If the camera is rebooted or power cycled, you will need to reconnect COM2TCP on your PC. COM2TCP
does
not
automatically detect the dropped connection.
Figure 46 Com2TCP Configuration
Set to “1000”
Set to the IP
Address of
Your Z3 Unit